Applicant | Address | Phone | Applicant Type | |
---|---|---|---|---|
Major Market Broadcasting of Florida, Inc. |
2118 WALSH AVENUE SUITE 208 SANTA CLARA, CA 95050 United States |
+1 (415) 886-7284 | fcc@chicago22.com | Corporation |
Applicant | Address | Phone | |
---|---|---|---|
[Confidential] |
|
|
|
Applicant | Address | Phone | |
---|---|---|---|
Tony Zummallen President QCommunications, LLC |
705 SE MELODY LN STE B LEES SUMMIT, MO 64063 United States |
+1 (816) 729-1177 | tony@qcomm.tv |
Question | Response |
---|---|
Will the station be sharing equipment with another broadcast television station or stations (e.g., a shared antenna, co-location on a tower, use of the same transmitter room, multiple transmitters feeding a combiner, etc.)? If yes, enter the facility ID's of the other stations and click 'prefill' to download those stations' licensing information. | No |
Briefly describe transition plan | WTBT-LD Transitioning from Channel 45 to Channel 8 as a result of Broadcast Repack. |
Section | Question | Response |
---|---|---|
Transmitter Related Expenses | Do you have transmitter related expenses? | Yes |
Section | Question | Response |
---|---|---|
Existing Transmitter Description | Type of change | Purchase New |
Use | Primary (Main) | |
Ownership | Owned | |
Is this transmitter currently shared with another station? | No | |
Is this transmitter currently in operating condition? | Yes | |
Existing Transmitter Manufacturer and Type | Manufacturer | |
Model | UTX5K | |
Year | 2007 | |
Type | Solid State | |
Solid State Cooling | Air Cooled | |
Solid State Power Capacity | 5 kW |
Section | Question | Response |
---|---|---|
New Transmitter | Use | Primary (Main) |
Change Type | Purchase New | |
Is this a request for upgraded equipment? | No | |
Manufacturer | ||
Model | UAXTE-6R44 | |
Transmitter Type | Solid State | |
Solid State Cooling | Air Cooled | |
Solid State Power capacity | 3.6 kW | |
Justification for New Transmitter | NEED NEW TRANSMITTER TO OPERATE ON CHANNEL 8 |
Section | Question | Response |
---|---|---|
Other Transmitter Costs | ||
Does the transmitter installation require a Transmitter Building Site Survey/Installation? | Yes | |
Electrical Service | Service Entrance (3 phases 800A 208V) | No |
Switchgear (industrial 800 amp) | No | |
Transformer (480V) | No | |
Rigid Conduit and Wiring | No | |
Other Electrical Service | Yes | |
Description | NEW WIRING OF NEW TRANSMITTER REQUIRED | |
HVAC Service | Does the replacement transmitter require HVAC Service? | No |
Transmitter Building Addition/Modification or Leasehold Improvement | Does the Transmitter Building require an addition, modification, other leashold improvement? | No |
Section | Question | Response |
---|---|---|
Antenna Related Expenses | Do you have antenna related expenses? | Yes |
Section | Question | Response |
---|---|---|
Existing Antenna Description | Type of change | Purchase New |
Antenna Use | Primary (Main) | |
Ownership | Owned | |
Is the existing antenna shared with another station or stations? | No | |
Is the existing antenna directional? | Yes | |
Is antenna in operating condition? | Yes | |
Is antenna located on or in close proximity to an antenna farm? | No | |
Existing Antenna Manufacturer and Type | ||
Mounting | Side Mount | |
Antenna position in stack | Not in Stack | |
Polarization | Horizontal | |
Type | Other | |
Other Antenna Type | Custom Panel | |
ERP: | 3.0 kW | |
Manufacturer | ||
Model | SWLP16EC | |
Year | 2007 |
Section | Question | Response |
---|---|---|
New Antenna Description | Use | Primary (Main) |
Change Type | Purchase New | |
Ownership | Owned | |
Is antenna shared? | No | |
Is antenna directional? | Yes | |
Will antenna be located on or in close proximity to an antenna farm? | No | |
New Antenna Manufacturer and Types | ||
Mounting | Side Mount | |
Antenna position in stack | Middle | |
Polarization | Elliptical | |
Type | Slotted Coaxial | |
ERP: | 5.0 kW | |
Manufacturer | ||
Model | 4x2 750 10325 | |
Year | 2021 | |
Justification for New Antenna | NEW CHANNEL 8 INCOMPATIBLE WITH EXISTING ANTENNA |
Section | Question | Response |
---|---|---|
Elbow Complex | Do you require the separate purchase of the Elbow Complex? | No |
Side Mount Brackets | Do you require the separate purchase of side mount brackets for a high power antenna? | Yes |
Pattern Scatter Analysis | Do you require separate purchase of pattern scatter analysis for a side mount high or medium power antenna? | Yes |
Sweep Test | Do you require the sweep testing of transmission line and antenna? | Yes |
Section | Question | Response |
---|---|---|
Transmission Line Related Expenses | Do you have transmission line related expenses? | Yes |
Section | Question | Response |
---|---|---|
Existing Transmission Line Description | Type of change | Purchase New |
Use | Primary (Main) | |
Ownership | Owned | |
Is the existing transmission line shared with another station or stations? | No | |
Is Transmission Line in operating condition? | Yes | |
Existing Transmission Line Manufacturer and Type | Manufacturer | |
Type | Flexible Foam | |
Diameter | Other | |
Other Diameter | 2 1/8 inches | |
Number of parallel runs | 1 | |
Length | 850 feet per run |
Section | Question | Response |
---|---|---|
New Transmission Line Costs | Use | Primary (Main) |
Change Type | Purchase New | |
Is this a request for upgraded equipment? | No | |
Type | Flexible Foam | |
Diameter | Other | |
Other Diameter | 3 1/8 inches | |
Number of parallel runs | 1 | |
Length | 1475 feet per run | |
Justification for New Transmission Line | New transmission line required for change in transmitter and antenna and change in location on tower | |
Interior RF Systems | Does the Installation of the Transmission Line require an additional or replacement Inside RF system including switching, patch panels, and dehydrators? | No |
Section | Question | Response |
---|---|---|
Tower Equipment or Rigging Costs Changes | Do you have tower equipment or rigging costs changes? | Yes |
Section | Question | Response |
---|---|---|
Existing Tower Description | Type of change | Modify Existing |
Tower Use | Primary (Main) | |
Ownership | Leased | |
Is this tower consider Complex? | No | |
Is this tower currently shared with any other stations? | Yes | |
One or more FM, AM or TV radio broadcaster(s) | Yes | |
Others Types of Users | No | |
Is tower documented for structural analysis? | Unknown | |
Is tower compliant with Rev G? | Unknown | |
Existing Tower Structure Registration | Do you have a tower registration number? | Yes |
ASR Number | 1057473 | |
Coordinates (NAD83) | Latitude (NAD83) | 27° 49' 10.8" N- |
Longitude (NAD83) | 082° 15' 38.0" W- | |
Overall Structure Height | 1592.83 feet | |
Support Structure Height | 1443.88 feet | |
Ground Elevation Above Mean Sea Level (AMSL) | 75.13 feet | |
Structure Type | GTOWER - Guyed Structure Used for Communication Purposes | |
Tower Owner | American Towers LLC | |
Date Constructed | 09/07/2011 |
Facility ID | Call Sign | Service |
---|---|---|
11125 | WCLF | DTV |
6601 | WXPX-TV | DTV |
66013 | WPOI | FM |
54948 | WSVT-LD | LPD |
63984 | WFUS | FM |
53819 | WMOR-TV | DTV |
11290 | WTSP | DTV |
16788 | WFTT-TV | DTV |
29732 | WFLZ-FM | FM |
23078 | WMTX | FM |
168552 | WTAM-LD | LPD |
74200 | WWRM | FM |
47459 | WMNF | FM |
Section | Question | Response |
---|---|---|
Engineering Study | Please what type of engineering study is required, if any: | Study need for guyed or free-standing tower |
Tower Reinforcements | Please select whether tower reinforcements are needed: | No reinforcements needed |
Section | Question | Response |
---|---|---|
Tower Rigging Costs | Complex Tower | N/A |
Helicopter Services Required | Are helicopter services required? | No |
Section | Question | Response |
---|---|---|
Outside Project Management Services | Do you require outside project management services? | No |
Outside RF consulting Engineering Services | Perform engineering study for displacement application | Yes |
Prepare engineering section of Form FCC Construction Permit Application | Yes | |
For Auxiliary Facility | No | |
For Main Facility | Yes | |
Prepare engineering section of Form FCC License to Cover Application | Yes | |
For Auxiliary Facility | No | |
For Main Facility | Yes | |
Prepare request for Special Temporary Authority | No | |
Prepare Form 601 | No | |
Attorney and Other Outside Consulting Services | Prepare and file Form FCC Construction Permit Application | Yes |
For Auxiliary Facility | No | |
For Main Facility | Yes | |
Prepare and file Form FCC License to Cover Application | Yes | |
For Auxiliary Facility | No | |
For Main Facility | Yes | |
Prepare request for Special Temporary Authority | No | |
Negotiation of Lease and other Matter for Shared Locations | No | |
Prepare or Review FCC Form 399 for Reimbursement | Yes | |
Form 399 assistance or other program management costs | Yes | |
RF Field Engineering Services | Comprehensive coverage verification via field study | Yes |
RF exposure measurements | Yes | |
Additional Field Engineering Service | Yes | |
Number of Days | 3 | |
Justification | ENGINEERING SERVICES FOR COMPLEX INSTALLATION ON MULTI-TENANT TOWER 3 DAYS @ $2000 per day |
Name | Description |
---|---|
INTERNAL PROJECT MGMT |
INTERNAL PROJECT MANAGEMENT SERVICES 50 HOURS @$100.00 p/h |
General Legal |
General Legal |
General Engineering Expense |
General Engineering |
Section | Question | Response |
---|---|---|
AM Pattern Disturbance | Is an Impact Study needed? | No |
Is Remediation needed? | No | |
Permit and Filing Costs | FCC Construction Permit Major Change | No |
FCC Construction Permit Minor Change | Yes | |
FCC License to Cover Application | Yes | |
FCC Special Temporary Authority Application | No | |
Other Miscellaneous Expenses | Does this relocation require paying Disposal Costs (for equipment and other waste, net of any salvage value)? | Yes |
Does this relocation require Equipment Delivery or Handling Charges not otherwise included in individual item costs? | Yes | |
Does this relocation require Equipment Storage? | No | |
Point to Point Microwave (STL/ICR) | Frequency Coordination for Unidirection System | No |
Frequency Coordination for Bi-Direction System | No | |
New Point to Point Microwave System | No |
Description | Predetermined Cost Estimate |
Estimated Cost | Estimated Cost Justification | Actual Cost | Actual Cost Justification |
---|---|---|---|---|---|
Sub-total | $116,000.00 | $144,679.69 | N/A | $99,017.19 | N/A |
Total for all systems | $636,448.90 | $703,069.54 | N/A | $438,712.04 | N/A |
Primary Transmitter UAXTE-6R44 | $116,000.00 | $144,679.69 | $99,017.19 | ||
Transmitter Building Site Survey/Installation | $10,000.00 | $40,662.50 | Actual costs | $0.00 | N/A |
Other Electrical Service: NEW WIRING OF NEW TRANSMITTER REQUIRED | $5,000.00 | $5,000.00 | N/A | N/A | N/A |
High VHF - Air Cooled Solid State Transmitter 1.1 - 4.4 kW | $101,000.00 | $99,017.19 | Transmitter costs per proposal Q-94320, plus shipping, tax and a change order. | $99,017.19 | N/A |
Actual Information Description | File Name |
---|---|
Transmitter Building Site Survey/Installation | |
Other Electrical Service: NEW WIRING OF NEW TRANSMITTER REQUIRED | Information not provided. |
High VHF - Air Cooled Solid State Transmitter 1.1 - 4.4 kW |
Description | Predetermined Cost Estimate |
Estimated Cost | Estimated Cost Justification | Actual Cost | Actual Cost Justification |
---|---|---|---|---|---|
Sub-total | $74,741.00 | $74,741.00 | N/A | $30,693.00 | N/A |
Total for all systems | $636,448.90 | $703,069.54 | N/A | $438,712.04 | N/A |
Primary Antenna 4x2 750 10325 | $74,741.00 | $74,741.00 | $30,693.00 | ||
Side Mount antenna brackets | $4,625.00 | $4,625.00 | N/A | N/A | N/A |
High VHF-Low Power, Side Mount, Slotted Coaxial, 5.0kW input, Elliptical | $30,693.00 | $30,693.00 | Per actual costs | $30,693.00 | N/A |
High VHF-Low Power, Side Mount, Slotted Coaxial, 3.0kW input, Horizontal | $30,693.00 | $30,693.00 | ***System Notice: Estimate adjusted and locked because line has been superseded.***Per actual costs | $0.00 | N/A |
Sweep test of transmission line and antenna | $5,730.00 | $5,730.00 | N/A | N/A | N/A |
Pattern scatter analysis for side mount (if not included in antenna base cost) | $3,000.00 | $3,000.00 | N/A | N/A | N/A |
Actual Information Description | File Name |
---|---|
Side Mount antenna brackets | Information not provided. |
High VHF-Low Power, Side Mount, Slotted Coaxial, 5.0kW input, Elliptical | |
High VHF-Low Power, Side Mount, Slotted Coaxial, 3.0kW input, Horizontal | |
Sweep test of transmission line and antenna | Information not provided. |
Pattern scatter analysis for side mount (if not included in antenna base cost) | Information not provided. |
Description | Predetermined Cost Estimate |
Estimated Cost | Estimated Cost Justification | Actual Cost | Actual Cost Justification |
---|---|---|---|---|---|
Sub-total | $90,862.00 | $143,324.00 | N/A | $71,662.00 | N/A |
Total for all systems | $636,448.90 | $703,069.54 | N/A | $438,712.04 | N/A |
Primary Transmission Line | $90,862.00 | $143,324.00 | $71,662.00 | ||
Flexible Foam Transmission Line - 3 1/8" 1 parallel runs 1475 feet | $71,662.00 | $71,662.00 | Per actual costs | $71,662.00 | N/A |
Flexible Foam Transmission Line - dielectric, 1 5/8" | $19,200.00 | $71,662.00 | ***System Notice: Estimate adjusted and locked because line has been superseded.***Per actual costs | $0.00 | N/A |
Actual Information Description | File Name |
---|---|
Flexible Foam Transmission Line - 3 1/8" 1 parallel runs 1475 feet | |
Flexible Foam Transmission Line - dielectric, 1 5/8" |
Description | Predetermined Cost Estimate |
Estimated Cost | Estimated Cost Justification | Actual Cost | Actual Cost Justification |
---|---|---|---|---|---|
Sub-total | $166,450.00 | $149,631.45 | N/A | $140,931.45 | N/A |
Total for all systems | $636,448.90 | $703,069.54 | N/A | $438,712.04 | N/A |
Primary Tower GTOWER | $166,450.00 | $149,631.45 | $140,931.45 | ||
Study needed for guyed or free-standing tower | $8,700.00 | $8,700.00 | N/A | N/A | N/A |
Tower Rigging Tall Tower (greater than 500') | $157,750.00 | $140,931.45 | Per costs on invoices | $140,931.45 | N/A |
Actual Information Description | File Name |
---|---|
Study needed for guyed or free-standing tower | Information not provided. |
Tower Rigging Tall Tower (greater than 500') |
Description | Predetermined Cost Estimate |
Estimated Cost | Estimated Cost Justification | Actual Cost | Actual Cost Justification |
---|---|---|---|---|---|
Sub-total | $164,950.90 | $167,248.40 | N/A | $81,908.40 | N/A |
Total for all systems | $636,448.90 | $703,069.54 | N/A | $438,712.04 | N/A |
Outside Professional Services | $164,950.90 | $167,248.40 | $81,908.40 | ||
General Legal | $2,158.00 | $2,158.00 | Per actual costs | $1,440.50 | N/A |
INTERNAL PROJECT MGMT | $22,270.00 | $22,270.00 | Per actual costs for external project management | $22,270.00 | N/A |
Additional Field Engineering Service, 3 Days | $6,000.00 | $6,000.00 | N/A | N/A | N/A |
RF Exposure Measurements | $12,100.00 | $12,100.00 | N/A | N/A | N/A |
Comprehensive coverage verification via field study, if needed | $52,600.00 | $52,600.00 | N/A | N/A | N/A |
Attorney Fees -Prepare and File FCC Form 2100 (main), License to Cover Application | $1,577.50 | $1,577.50 | N/A | $0.00 | N/A |
Attorney Fees - Prepare and File FCC Form 2100 (main), Construction Permit Application | $3,025.00 | $3,025.00 | N/A | $950.00 | N/A |
Prepare/ Review 399 reimbursement form | $1,710.00 | $1,710.00 | N/A | N/A | N/A |
Form 399 assistance or other Program Management costs | $6,560.40 | $6,560.40 | Per actual costs | $6,560.40 | N/A |
Prepare engineering section of FCC Form 2100 (main), License to Cover Application | $1,052.50 | $1,052.50 | N/A | N/A | N/A |
Perform engineering study for displacement application | $1,800.00 | $4,000.00 | Based on actual expense | $4,000.00 | Additional engineering work required due to potential interference issue and evaluation of options. |
Prepare engineering section of FCC Form 2100 (main), Construction Permit Application | $2,102.50 | $2,200.00 | Based on actual cost | $2,200.00 | Actual engineering expense incurred. |
General Engineering Expense | $51,995.00 | $51,995.00 | Costs per actual invoices | $44,487.50 | N/A |
Actual Information Description | File Name |
---|---|
General Legal | |
INTERNAL PROJECT MGMT | |
Additional Field Engineering Service, 3 Days | Information not provided. |
RF Exposure Measurements | Information not provided. |
Comprehensive coverage verification via field study, if needed | Information not provided. |
Attorney Fees -Prepare and File FCC Form 2100 (main), License to Cover Application | |
Attorney Fees - Prepare and File FCC Form 2100 (main), Construction Permit Application | |
Prepare/ Review 399 reimbursement form | Information not provided. |
Form 399 assistance or other Program Management costs | |
Prepare engineering section of FCC Form 2100 (main), License to Cover Application | Information not provided. |
Perform engineering study for displacement application | |
Prepare engineering section of FCC Form 2100 (main), Construction Permit Application | |
General Engineering Expense |
Description | Predetermined Cost Estimate |
Estimated Cost | Estimated Cost Justification | Actual Cost | Actual Cost Justification |
---|---|---|---|---|---|
Sub-total | $23,445.00 | $23,445.00 | N/A | $14,500.00 | N/A |
Total for all systems | $636,448.90 | $703,069.54 | N/A | $438,712.04 | N/A |
Other Expenses | $23,445.00 | $23,445.00 | $14,500.00 | ||
Equipment Delivery and Handling Charges | $14,500.00 | $14,500.00 | Per actual costs | $14,500.00 | N/A |
Disposal Costs (for equipment and other waste, net of any salvage value) | $7,500.00 | $7,500.00 | N/A | N/A | N/A |
FCC Filing Fees - Form 2100 license to cover application | $335.00 | $335.00 | N/A | N/A | N/A |
FCC Filing Fees - Form 2100 minor change CP application | $1,110.00 | $1,110.00 | N/A | N/A | N/A |
Actual Information Description | File Name |
---|---|
Equipment Delivery and Handling Charges | |
Disposal Costs (for equipment and other waste, net of any salvage value) | Information not provided. |
FCC Filing Fees - Form 2100 license to cover application | Information not provided. |
FCC Filing Fees - Form 2100 minor change CP application | Information not provided. |
Predetermined Cost Estimate |
Estimated Cost | Actual Cost | |
---|---|---|---|
Total for all systems | $636,448.90 | $703,069.54 | $438,712.04 |
Question | Response |
---|---|
The facility has ceased operating on its pre-auction channel. | Yes |
Construction of final facilities or all necessary modifications are complete. | Yes |
All receipts for reimbursement have been submitted no further costs are expected to be incurred. Note this will lock the Form 399 from further editing and begin close-out procedures with the Fund Administrator. | Yes |
Section | Question | Response |
---|---|---|
Submission of Estimated Expenses Statements | WILLFUL FALSE STATEMENTS ON THIS FORM ARE PUNISHABLE BY FINE AND/OR IMPRISONMENT (U.S. CODE, TITLE 18, SECTION 1001), AND/OR REVOCATION OF ANY STATION LICENSE OR CONSTRUCTION PERMIT (U.S. CODE, TITLE 47, SECTION 312(a)(1), AND/OR FORFEITURE (U.S. CODE, TITLE 47, SECTION 503), AND ANY FALSE STATEMENTS COULD SUBJECT THIS ENTITY TO LIABILITY UNDER THE FALSE CLAIMS ACT. |
|
I declare, under penalty of perjury, that I am an authorized representative of the above-named applicant for the Authorization(s) specified above. | Ravi Kapur President 05/18/2023 |
Section | Question | Response |
---|---|---|
Submission of Final Allocation or Accounting Information Statements | WILLFUL FALSE STATEMENTS ON THIS FORM ARE PUNISHABLE BY FINE AND/OR IMPRISONMENT (U.S. CODE, TITLE 18, SECTION 1001), AND/OR REVOCATION OF ANY STATION LICENSE OR CONSTRUCTION PERMIT (U.S. CODE, TITLE 47, SECTION 312(a)(1), AND/OR FORFEITURE (U.S. CODE, TITLE 47, SECTION 503), AND ANY FALSE STATEMENTS COULD SUBJECT THIS ENTITY TO LIABILITY UNDER THE FALSE CLAIMS ACT. |
|
I declare, under penalty of perjury, that I am an authorized representative of the above-named applicant for the Authorization(s) specified above. | Ravi Kapur President 05/18/2023 |