Applicant Information

Back to Top

Applicant Name, Type, and Contact Information

Applicant Address Phone Email Applicant Type

ION MEDIA LICENSE COMPANY, LLC

Doing Business As: ION MEDIA LICENSE COMPANY, LLC

Bianca Frye

601 Clearwater Park Road

West Palm Beach, FL 33401

United States

+1 (561) 682-4110 BiancaFrye@ionmedia.com Limited Liability Company

Reimbursement Contact Information

Reimbursement Contact Name and Information

Applicant Address Phone Email

[Confidential]

 

 

 


Preparer Contact Information

Back to Top

Preparer Contact Name and Information

Applicant Address Phone Email

The Preparer is same as the reimbursement contact.

 

 

 

Broadcaster Information and Transition Plan

Back to Top
Question Response
Will the station be sharing equipment with another broadcast television station or stations (e.g., a shared antenna, co-location on a tower, use of the same transmitter room, multiple transmitters feeding a combiner, etc.)? If yes, enter the facility ID's of the other stations and click 'prefill' to download those stations' licensing information. Yes
Briefly describe transition plan Relocate from current site (ESB) to 1WTC. Will be using the master antenna equipment at the new facility and installing new transmitters and RF systems to the master combiner. See attached Transition Plan Exhibit for more information.

Transmitters

Back to Top
Section Question Response
Transmitter Related Expenses Do you have transmitter related expenses? Yes

Auxiliary Transmitter

Back to Top

Add Transmitter Information

Section Question Response
Existing Transmitter Description Type of change Purchase New
Use Auxiliary (Backup)
Description of Use Auxiliary Transmitter
Ownership Owned
Owner N/A
Site N/A
Is this transmitter currently shared with another station? No
Is this transmitter currently in operating condition? Yes
Existing Transmitter Manufacturer and Type Manufacturer
Model Ultimate
Year 2002
Type Solid State
Solid State Cooling Liquid Cooled
Solid State Power Capacity 10 kW

Auxiliary Transmitter

Back to Top

New Transmitter Costs

Section Question Response
New Transmitter Use Auxiliary (Backup)
Change Type Purchase New
Is this a request for upgraded equipment? No
Manufacturer
Model THU9-12 EVO
Transmitter Type Solid State
Solid State Cooling Liquid Cooled
Solid State Power capacity 19 kW
Justification for New Transmitter See attached Ultimate and Optimum Transmitter Exhibit. New location requires additional TPO.

Auxiliary Transmitter

Back to Top

Other Transmitter Costs

Section Question Response
Electrical Service Service Entrance (3 phases 800A 208V) No
Switchgear (industrial 800 amp) Yes
Transformer (480V) Yes
Power 150 kVA
Rigid Conduit and Wiring No
Size N/A
Length N/A
Other Electrical Service Yes
Description Electrical and mechanical installation for replacement transmitter.
HVAC Service Does the replacement transmitter require HVAC Service? No
Type N/A
Size N/A
Other Size N/A
Transmitter Building Addition/Modification or Leasehold Improvement Does the Transmitter Building require an addition, modification, other leashold improvement? No
Size N/A
Channel 14 Costs Is an RF Consulting Engineer needed? N/A
Is a channel 14 Mask Filer needed? N/A
Is additional field engineering time needed? N/A
Number of Days N/A

Auxiliary Transmitter

Back to Top

Other Transmitter Cost Not Listed

Information not provided.

Primary Transmitter

Back to Top

Existing Transmitter Information

Section Question Response
Existing Transmitter Description Type of change Purchase New
Use Primary (Main)
Description of Use N/A
Ownership Owned
Owner N/A
Site N/A
Is this transmitter currently shared with another station? No
Is this transmitter currently in operating condition? Yes
Existing Transmitter Manufacturer and Type Manufacturer
Model DCX
Year 2002
Type Inductive Output Tube
IOT Power Type Three
Power Capacity 60 kW

Primary Transmitter

Back to Top

New Transmitter Costs

Section Question Response
New Transmitter Use Primary (Main)
Change Type Purchase New
Is this a request for upgraded equipment? Yes
Manufacturer
Model THU9-16 EVO
Transmitter Type Solid State
Solid State Cooling Liquid Cooled
Solid State Power capacity 25.5 kW
Justification for New Transmitter We do not agree with your "upgrade" characterization. We have calculated our ERP and headroom requirements in accordance with the reimbursement rules. See attached revised Transmitter Exhibit, including Upgrade Disclaimer.

Primary Transmitter

Back to Top

Other Transmitter Costs

Section Question Response
Electrical Service Service Entrance (3 phases 800A 208V) No
Switchgear (industrial 800 amp) Yes
Transformer (480V) Yes
Power 150 kVA
Rigid Conduit and Wiring No
Size N/A
Length N/A
Other Electrical Service Yes
Description Electrical and mechanical installation for replacement transmitter.
HVAC Service Does the replacement transmitter require HVAC Service? No
Type N/A
Size N/A
Other Size N/A
Transmitter Building Addition/Modification or Leasehold Improvement Does the Transmitter Building require an addition, modification, other leashold improvement? No
Size N/A
Channel 14 Costs Is an RF Consulting Engineer needed? N/A
Is a channel 14 Mask Filer needed? N/A
Is additional field engineering time needed? N/A
Number of Days N/A

Primary Transmitter

Back to Top

Other Transmitter Cost Not Listed

Name Description

Removal of Existing Equipment

Removal of existing transmitters and equipment

RF Interconnect

Interconnect between transmitter and combiner

Antennas

Back to Top
Section Question Response
Antenna Related Expenses Do you have antenna related expenses? Yes

Primary Antenna

Back to Top

Existing Antenna Information

Section Question Response
Existing Antenna Description Type of change Lease New
Antenna Use Primary (Main)
Description of Use N/A
Ownership Owned
Owner N/A
Site N/A
Is the existing antenna shared with another station or stations? No
Is the existing antenna directional? Yes
Is antenna in operating condition? Yes
Is antenna located on or in close proximity to an antenna farm? Yes
Existing Antenna Manufacturer and Type Class Full Power
Mounting Side Mount
Antenna position in stack Not in Stack
Polarization Elliptical
Type Slotted Coaxial
Number of Stations Supported N/A
Number of Panels N/A
Design power capacity in use N/A
Lower Limit N/A
Upper Limit N/A
Other Antenna Type N/A
ERP: 180.0 kW
Manufacturer
Model TFU-24DSC-R CT170 SP-DC
Year 2003

Primary Antenna

Back to Top

New Antenna Costs

Section Question Response
New Antenna Description Use Primary (Main)
Description of Use N/A
Change Type Lease New
Is this a request for upgraded equipment? No
Ownership Leased
Owner Durst - 1WTC
Is antenna shared? Yes
Is antenna directional? No
Will antenna be located on or in close proximity to an antenna farm? Yes
New Antenna Manufacturer and Types Class Full Power
Mounting Top Mount
Antenna position in stack Top
Polarization Elliptical
Type Broadband Panel
Number of Stations Supported 4
Number of Panels/Bays 40
Lower Limit 470.00 MHz
Upper Limit 698.00 MHz
Design power capacity in use 35.0 %
Other Antenna Type N/A
ERP: 100.0 kW
Manufacturer
Model PEP40E
Year 2017
Justification for New Antenna Current slot antenna can not be re-channeled.

Primary Antenna

Back to Top

Other Antenna Costs

Section Question Response
Combiner for Shared Antenna Do you need a Combiner for a Shared Antenna? Yes
Type Additional Module
Number of channels supported 4
Frequencies of channels supported RF channel
Frequency N/A
Do you need a combiner output splitter/switcher for dual feed lines? No
Elbow Complex Do you require the separate purchase of the Elbow Complex? No
Broadband or Single Channel? N/A
Feed Line Size N/A
Side Mount Brackets Do you require the separate purchase of side mount brackets for a high power antenna? No
Pattern Scatter Analysis Do you require separate purchase of pattern scatter analysis for a side mount high or medium power antenna? No
Sweep Test Do you require the sweep testing of transmission line and antenna? Yes

Enter a list of RF channel numbers.

RF Channel Number
36
35
34

Primary Antenna

Back to Top

Other Antenna Cost Not Listed

Information not provided.

Interim Antenna

Back to Top

New Antenna Costs

Section Question Response
New Antenna Description Use Interim
Description of Use N/A
Change Type Lease New
Ownership Leased
Owner Durst - 1WTC
Is antenna shared? Yes
Is antenna directional? No
Will antenna be located on or in close proximity to an antenna farm? Yes
New Antenna Manufacturer and Type Class Full Power
Mounting Top Mount
Antenna position in stack Middle
Polarization Elliptical
Type Broadband Panel
Number of Stations Supported 4
Number of Panels/Bays 96
Lower Limit 470.00 MHz
Upper Limit 698.00 MHz
Design power capacity in use 35.0 %
Other Antenna Type N/A
ERP: 100.0 kW
Manufacturer
Model PEP96L
Year 2017
Justification for New Antenna Required for on-air operation during channels transition.

Interim Antenna

Back to Top

Other Antenna Costs

Section Question Response
Combiner for Shared Antenna Do you need a Combiner for a Shared Antenna? Yes
Type Additional Module
Number of channels supported 4
Frequencies of channels supported RF channel
Frequency N/A
Do you need a combiner output splitter/switcher for dual feed lines? No
Elbow Complex Do you require the separate purchase of the Elbow Complex? No
Broadband or Single Channel? N/A
Feed Line Size N/A
Side Mount Brackets Do you require the separate purchase of side mount brackets for an antenna? No
Pattern Scatter Analysis Do you require separate purchase of pattern scatter analysis for a side mount high or medium power antenna? No
Sweep Test Do you require the sweep testing of transmission line and antenna? Yes

Enter a list of RF channel numbers.

RF Channel Number
35
34
36

Interim Antenna

Back to Top

Other Antenna Cost Not Listed

Information not provided.

Transmission Line

Back to Top
Section Question Response
Transmission Line Related Expenses Do you have transmission line related expenses? No

Tower Equipment And Rigging Costs

Back to Top
Section Question Response
Tower Equipment or Rigging Costs Changes Do you have tower equipment or rigging costs changes? Yes

Primary Tower

Back to Top

Add Tower

Section Question Response
Existing Tower Description Type of change Modify Existing
Tower Use Primary (Main)
Description of Use N/A
Ownership Leased
Is this tower consider Complex? Located on Building
Is this tower currently shared with any other stations? Yes
One or more FM, AM or TV radio broadcaster(s) Yes
Others Types of Users No
Is tower documented for structural analysis? Yes
Is tower compliant with Rev G? Yes
Existing Tower Structure Registration Do you have a tower registration number? Yes
ASR Number 1263701
Coordinates (NAD83) Latitude (NAD83) 40° 42' 46.8" N-
Longitude (NAD83) 074° 00' 47.3" W-
Overall Structure Height 1791.97 feet
Support Structure Height 1334.63 feet
Ground Elevation Above Mean Sea Level (AMSL) 14.11 feet
Structure Type BTWR - Building with Tower
Tower Owner Port Authority of New York and New Jersey
Date Constructed 05/10/2013

FM, AM or TV radio broadcasters. Facility ID's, Call Signs and Services of other broadcast stations with whom the tower is shared

Facility ID Call Sign Service
9610 WCBS-TV DTV
73881 WPIX DTV
73333 WNJU DTV
47535 WNBC DTV
18795 WNET DTV
1328 WABC-TV DTV

Primary Tower

Back to Top

Tower Modification Costs

Section Question Response
Engineering Study Please what type of engineering study is required, if any: No study needed
Tower Reinforcements Please select whether tower reinforcements are needed: No reinforcements needed

Primary Tower

Back to Top

Tower Rigging Costs

Section Question Response
Tower Rigging Costs Complex Tower Located on Building
Helicopter Services Required Are helicopter services required? No

Primary Tower

Back to Top

Other Tower Expenses Not Listed

Name Description

Professional Engineering Services for the Removal of Exterior Systems

Professional Engineering Services for the Removal of Exterior Systems

Primary Tower

Back to Top

Existing Tower

Section Question Response
Existing Tower Description Type of change Move Equipment
Tower Use Primary (Main)
Description of Use N/A
Ownership Leased
Is this tower consider Complex? Located on Building
Is this tower currently shared with any other stations? Yes
One or more FM, AM or TV radio broadcaster(s) Yes
Others Types of Users No
Is tower documented for structural analysis? Yes
Is tower compliant with Rev G? Unknown
Existing Tower Structure Registration Do you have a tower registration number? Yes
ASR Number 1007048
Coordinates (NAD83) Latitude (NAD83) 40° 44' 54.0" N-
Longitude (NAD83) 073° 59' 09.0" W-
Overall Structure Height 1453.39 feet
Support Structure Height 1249.98 feet
Ground Elevation Above Mean Sea Level (AMSL) 50.85 feet
Structure Type B - Building
Tower Owner EMPIRE STATE BUILDING COMPANY
Date Constructed 01/01/1931

FM, AM or TV radio broadcasters. Facility ID's, Call Signs and Services of other broadcast stations with whom the tower is shared

Facility ID Call Sign Service
19615 WQHT FM
70493 WZME DTV
59953 WHTZ FM
60555 WFUT-DT DTV
74215 WXTV-DT DTV
47535 WNBC DTV
67866 WNDT-CD DTV
9610 WCBS-TV DTV
67846 WFAN-FM FM
46978 WQXR-FM FM
18795 WNET DTV
6373 WWPR-FM FM
56571 WLTW FM
73887 WPLJ FM
28203 WBLS FM
23004 WAXQ FM
1328 WABC-TV DTV
6595 WKTU FM
22206 WNYW DTV
9611 WCBS-FM FM
51249 WBAI FM
73355 WNYC-FM FM
74197 WWOR-TV DTV
73333 WNJU DTV
51663 WPAT-FM FM
61641 WSKQ-FM FM
29022 WXNY-FM FM
43952 WMBC-TV DTV
25442 WNEW-FM FM
63781 WEPN-FM FM

Primary Tower

Back to Top

Tower Rigging Costs

Section Question Response
Tower Rigging Costs Complex Tower Located on Building
Helicopter Services Required Are helicopter services required? No

Primary Tower

Back to Top

Other Tower Expenses Not Listed

Information not provided.

Outside Professional Services Costs

Back to Top
Section Question Response
Outside Project Management Services Do you require outside project management services? No
Number of Hours N/A
Explanation N/A
Outside RF consulting Engineering Services Perform engineering study for new channel assignment and antenna development Yes
Prepare engineering section of Form FCC Construction Permit Application Yes
For Auxiliary Facility Yes
For Main Facility Yes
Prepare engineering section of Form FCC License to Cover Application Yes
For Auxiliary Facility Yes
For Main Facility Yes
Prepare request for Special Temporary Authority Yes
Quantity 2
Do you have Distributed Transmission System engineering services? N/A
Critical Facility N/A
Terrain-Shielded Facility N/A
Attorney and Other Outside Consulting Services Prepare and file Form FCC Construction Permit Application Yes
For Auxiliary Facility Yes
For Main Facility Yes
Prepare and file Form FCC License to Cover Application Yes
For Auxiliary Facility Yes
For Main Facility Yes
Prepare request for Special Temporary Authority Yes
Quantity 2
NEPA Section 106 environmental review Yes
Environmental Assessment Yes
ASR Modification Yes
FAA Consultation (including preparation of FAA Form 7460) Yes
Negotiation of Lease and other Matter for Shared Locations Yes
Prepare or Review FCC Form 399 for Reimbursement Yes
Address transition timing and coordination issues w/ other stations and wireless providers Yes
RF Field Engineering Services Comprehensive coverage verification via field study Yes
RF exposure measurements Yes
Additional Field Engineering Service No
Number of Days N/A
Justification N/A

Outside Professional Services Costs

Back to Top

Other Professional Services Expenses Not Listed

Name Description

Installation Supervision

management of transmitter installation

Engineering Services

Design and specifying electrical, mechanical and RF systems

Commissioning of combiner

Commissioning of the modules into the combiner for both the main and auxiliary.

Other Expenses

Back to Top
Section Question Response
AM Pattern Disturbance Is an Impact Study needed? No
Is Remediation needed? No
Facility Expenses Name N/A
Other Distributed Transmission System Expenses Not listed N/A
Name N/A
Is Notification of a Medical Facility required as a result of DTV broadcasting? Yes
Permit and Filing Costs Local Zoning Yes
Non-zoning permits Yes
BLM or NFS Coordination No
FCC Construction Permit Minor Change Yes
FCC License to Cover Application Yes
FCC Special Temporary Authority Application Yes
Other Miscellaneous Expenses Does this relocation require paying Disposal Costs (for equipment and other waste, net of any salvage value)? Yes
Does this relocation require Equipment Delivery or Handling Charges not otherwise included in individual item costs? Yes
Does this relocation require Equipment Storage? Yes
Does this relocation require the Development and Airing of an Announcement regarding an upcoming channel change? Yes
Does this relocation require MVPD Notification of a Channel Change? Yes

Other Expenses

Back to Top

Other Expenses Not Listed

Information not provided.

Cost Information

Back to Top

Transmitters

Where no predetermined cost estimate is available, any estimate provided will also become the predetermined cost (displayed in italics).
Description Predetermined
Cost Estimate
Estimated Cost Estimated Cost Justification Actual Cost Actual Cost Justification
Sub-total $2,666,014.95 $1,800,431.61 N/A $1,632,828.44 N/A
Total for all systems $6,398,219.81 $2,850,334.40 N/A $2,335,696.98 N/A
Primary Transmitter THU9-16 EVO $1,765,980.74 $1,266,578.50 $1,098,975.33
RF Interconnect $120,174.57 $120,174.57 See attached Myat, Inc. Invoices #00084355, #00084366, #CR00000528, #00084369, and #00084408. Attached BGS Invoice #0406842. Attached RFS invoices #27010377, #27010375, #7240357, and #16526892 $120,174.57 N/A
Removal of Existing Equipment $475,096.17 $475,096.17 See attached Interior - Advent Industrial P.O. #'s #1011281, #1011251, #1010822, #1010821. Also see attached Interior - Advent Industrial #5588, #5573. $307,493.00 N/A
Other Electrical Service: Electrical and mechanical installation for replacement transmitter. $159,960.00 $159,960.00 See attached Bel-Air Construction Inc. Invoices #1081-01, #1081-02, #1081-03, #1081-CO3. $159,960.00 N/A
Transformer 3 phase/480v - 150 KVA $25,550.00 $6,737.00 Per FCC procedure, as the actual cost for this expense is greater than what was previously estimated, ION has updated the cost estimate to reflect our latest invoices. Please see Feldman Brothers #2369067-00 & Feldman Brothers #2350187-00 attachments. $6,737.00 N/A
UHF - Liquid Cooled Solid State Transmitter 21 - 31 kW $947,000.00 $504,610.76 Estimated cost updated to reflect actual costs. See attached Rohde & Schwarz #9500063568, Rohde & Schwarz #9500076567, and Rohde & Schwarz #9500087895. $504,610.76 N/A
Switchgear - industrial 800 amp $38,200.00 $0.00 N/A $0.00 N/A
Auxiliary Transmitter THU9-12 EVO $900,034.21 $533,853.11 $533,853.11
Other Electrical Service: Electrical and mechanical installation for replacement transmitter. $152,284.21 $152,284.21 Updated to reflect actual costs to date. $152,284.21 N/A
Transformer 3 phase/480v - 150 KVA $25,550.00 $6,737.00 Per FCC procedure, as the actual cost for this expense is greater than what was previously estimated, ION has updated the cost estimate to reflect our latest invoice. Please see Feldman Brothers #2369067-00 & Feldman Brothers #2350187-00 attachments. $6,737.00 N/A
UHF - Liquid Cooled Solid State Transmitter 14.2 - 20 kW $684,000.00 $374,831.90 See Rohde & Schwarz Invoices #9500063568, Rohde & Schwarz #9500076567, and Rohde & Schwarz #9500087895. $374,831.90 N/A
Switchgear - industrial 800 amp $38,200.00 $0.00 N/A $0.00 N/A

Components

Actual Information Description File Name
RF Interconnect

Component Description:
Cost of additional components for RF Interconnect. Supporting documentation is attached. This invoice has been paid.
Amount:
$784.00

Component Description:
Cost of RF Interconnect Air-cooled Motor Flanged Input. Supporting documentation attached. This invoice has been paid.
Amount:
$17,438.38

Component Description:
Cost of additional components for RF Interconnect. Supporting documentation is attached. This invoice has been paid.
Amount:
$1,200.00

Component Description:
Cost of RF Interconnect Components to Join Transmitter with Transmission Line. Supporting documentation attached. This invoice has been paid.
Amount:
$7,246.13

Component Description:
50% "prior to ship payment" for rigid transmission line patch panel (RF interconnect) to combiner. Detailed cost breakdown and supporting documentation attached. This invoice has been paid.
Amount:
$46,228.50

Component Description:
Cost of RF Interconnect components to self-monitor quality of RF Signal to Transmitter. Supporting documentation attached. This invoice has been paid.
Amount:
$1,338.02

Component Description:
40% "with order payment" for rigid transmission line patch panel (RF interconnect) to combiner. Detailed cost breakdown and supporting documentation attached. This invoice has been paid.
Amount:
$36,982.80

Component Description:
Credit Memo against Myat, Inc. #00084355 "Cost of RF Interconnect Components to Join Transmitter with Transmission Line". / Approved on 2/24/2018.
Amount:
($1,800.00)

Component Description:
10% "acceptance payment" for rigid transmission line patch panel (RF interconnect) to combiner. Detailed cost breakdown and supporting documentation attached. This invoice has been paid.
Amount:
$9,245.70

Component Description:
Cost of Additional RF Interconnect Components to Join Transmitter with Transmission Line. Supporting documentation attached. This invoice has been paid.
Amount:
$1,511.04
Removal of Existing Equipment

Component Description:
Progress payment #3 for removal of equipment from transmitter room at Empire State Building (net of non-removal costs). Per FCC guidance, detailed cost breakdown, explanation of variance and supporting documentation attached. This invoice has been paid.
Amount:
$6,563.65

Component Description:
Progress payment #3 for removal of equipment from transmitter room at ESB (net of non-removal costs). In response to RFI, this invoice is being resubmitted excluding any related invoices. Supporting documentation and cost breakdown attached.
Amount:
$22,964.45

Component Description:
Progress payment #2 for removal of equipment from transmitter room at Empire State Building (net of non-removal costs). Per FCC guidance, detailed cost breakdown and supporting documentation attached. This invoice has been paid.
Amount:
$29,442.05

Component Description:
Final payment for removal of equipment from transmitter room / progress payment #2 for removal of transmission line (excluding non-removal costs). Detailed cost breakdown, explanation of variance and supporting documentation attached.
Amount:
$60,453.30

Component Description:
20% startup payment for removal of transmission line (net of non-removal costs). Per FCC guidance, detailed cost breakdown, explanation of variance and supporting documentation attached. This invoice has been paid.
Amount:
$15,274.00

Component Description:
Progress payment #1 for removal of equipment from transmitter room at Empire State Building (net of non-removal costs). Per FCC guidance, detailed cost breakdown, explanation of variance and supporting documentation attached. This invoice has been paid.
Amount:
$19,750.95

Component Description:
25% payment for AIA/ENG services for permitting needed for removal of equipment from Empire State Building. Per FCC guidance, detailed cost breakdown and supporting documentation attached. This invoice has been paid.
Amount:
$12,725.00

Component Description:
20% final payment for AIA/ENG services for permitting necessary for removal of equipment from Empire State Building. Supporting documentation attached. This invoice has been paid.
Amount:
$10,180.00

Component Description:
25% startup payment for AIA/ENG services for permitting necessary for removal of equipment from Empire State Building. Supporting documentation attached. This invoice has been paid.
Amount:
$12,725.00

Component Description:
Progress payment #3 for removal of equipment from transmitter room at Empire State Building. Supporting documentation attached.
Amount:
$36,414.45

Component Description:
20% startup payment for removal of equipment from transmitter room (net of non-removal costs). Per FCC guidance, detailed cost breakdown, explanation of variance and supporting documentation attached. This invoice has been paid.
Amount:
$26,334.60

Component Description:
20% startup payment for removal of transmission line, equipment and restoration of Empire State Building facility. Supporting documentation attached. This invoice has been paid.
Amount:
$71,061.00

Component Description:
55% progress payment for AIA/ENG services for permitting necessary for removal of equipment from Empire State Building. Supporting documentation attached. This invoice has been paid.
Amount:
$27,995.00

Component Description:
20% final payment for AIA/ENG services for permitting necessary for removal of equipment from Empire State Building (net of non-removal costs). Per FCC guidance, detailed cost breakdown and supporting documentation attached. This invoice has been paid.
Amount:
$7,180.00

Component Description:
55% progress payment for AIA/ENG services for permitting necessary for removal of equipment from Empire State Building. Per FCC guidance, detailed cost breakdown and supporting documentation attached. This invoice has been paid.
Amount:
$27,995.00

Component Description:
Progress payment #2 for removal of equipment from transmitter room at Empire State Building. Supporting documentation attached. This invoice has been paid.
Amount:
$9,901.80

Component Description:
Final payment for removal of transmission line (net of non-removal costs). Detailed cost breakdown and supporting documentation attached. This invoice has been paid.
Amount:
$78,810.00

Component Description:
Progress payment #1 for removal of equipment from transmitter room at Empire State Building. Supporting documentation attached. This invoice has been paid.
Amount:
$19,750.95
Other Electrical Service: Electrical and mechanical installation for replacement transmitter.

Component Description:
Payment No. 3 for electrical installation of primary transmitter. Detailed cost breakdown and supporting documentation attached. This invoice has been paid.
Amount:
$15,266.32

Component Description:
Full cost of remaining electrical installation of primary transmitter and RF system. Supporting documentation attached. This invoice has been paid.
Amount:
$10,368.00

Component Description:
Payment No. 1 for electrical installation of primary transmitter. Detailed cost breakdown and supporting documentation attached. This invoice has been paid.
Amount:
$29,704.75

Component Description:
Payment No. 2 for electrical installation of primary transmitter. Detailed cost breakdown and supporting documentation attached. This invoice has been paid.
Amount:
$104,620.93
Transformer 3 phase/480v - 150 KVA

Component Description:
Cost of transformers for primary transmitter. Supporting documentation and cost breakdown attached. This invoice has been paid.
Amount:
$2,243.42

Component Description:
Cost of transformers for primary transmitter. Supporting documentation and cost breakdown attached. This invoice has been paid.
Amount:
$4,493.58
UHF - Liquid Cooled Solid State Transmitter 21 - 31 kW

Component Description:
Full cost of primary transmitter channel change and proof of performance. Detailed cost breakdown and supporting documentation attached. This invoice has been paid.
Amount:
$17,173.50

Component Description:
75% "remaining balance" payment for Rohde & Schawrz primary transmitter. Supporting documentation and cost breakdown attached.
Amount:
$365,577.95

Component Description:
25% "down-payment" for Rohde & Schwarz Primary Transmitter. Supporting documentation and cost breakdown attached. This invoice has been paid.
Amount:
$121,859.31
Switchgear - industrial 800 amp Information not provided.
Other Electrical Service: Electrical and mechanical installation for replacement transmitter.

Component Description:
Payment No. 2 for electrical installation of auxiliary transmitter. Detailed cost breakdown and supporting documentation attached. This invoice has been paid.
Amount:
$104,620.92

Component Description:
Payment No. 1 for electrical installation of auxiliary transmitter. Detailed cost breakdown and supporting documentation attached. This invoice has been paid.
Amount:
$29,704.75

Component Description:
Payment No. 3 for electrical installation of auxiliary transmitter. Detailed cost breakdown and supporting documentation attached. This invoice has been paid.
Amount:
$15,266.33

Component Description:
Full cost to install Air Separator & Drip Pan to keep air out of Auxiliary Transmitter Cooling Lines. Supporting documentation attached. This invoice has been paid.
Amount:
$2,692.21
Transformer 3 phase/480v - 150 KVA

Component Description:
Cost of transformers for auxiliary transmitter. Supporting documentation and cost breakdown attached. This invoice has been paid.
Amount:
$2,243.42

Component Description:
Cost of transformers for auxiliary transmitter. Supporting documentation and cost breakdown attached. This invoice has been paid.
Amount:
$4,493.58
UHF - Liquid Cooled Solid State Transmitter 14.2 - 20 kW

Component Description:
75% "remaining balance" payment for Rhode & Schwarz Auxiliary transmitter. Supporting documentation and cost breakdown attached.
Amount:
$268,950.00

Component Description:
Full cost of auxiliary transmitter channel change and proof of performance. Detailed cost breakdown and supporting documentation attached. This invoice has been paid.
Amount:
$16,231.90

Component Description:
25% "down-payment" for Rohde & Schwarz Auxiliary Transmitter. Supporting documentation and cost breakdown attached. This invoice has been paid.
Amount:
$89,650.00
Switchgear - industrial 800 amp Information not provided.

Cost Information

Back to Top

Antennas

Where no predetermined cost estimate is available, any estimate provided will also become the predetermined cost (displayed in italics).
Description Predetermined
Cost Estimate
Estimated Cost Estimated Cost Justification Actual Cost Actual Cost Justification
Sub-total $2,361,860.00 $227,918.68 N/A $227,918.68 N/A
Total for all systems $6,398,219.81 $2,850,334.40 N/A $2,335,696.98 N/A
Interim Antenna PEP96L $1,180,930.00 $113,959.34 $113,959.34
Adding a module to existing combiner (without antenna) $84,200.00 $110,209.34 See attached Radio Frequency Systems Invoice #27010375, #27010377, #7240357. And DSI-RF Systems WTC WPXN Proposal $110,209.34 N/A
Sweep test of existing antenna $6,730.00 $3,750.00 Updated to reflect actual costs to date. $3,750.00 N/A
UHF - High Power Top Mount (200-1000 kW), Four Station broadband panel antenna, elliptically or circularly polarized $1,090,000.00 $0.00 N/A $0.00 N/A
Primary Antenna PEP40E $1,180,930.00 $113,959.34 $113,959.34
Adding a module to existing combiner (without antenna) $84,200.00 $110,209.34 See attached Radio Frequency Systems Invoice #27010375, #27010377, #7240357. and DSI-RF Systems WTC WPXN Proposal $110,209.34 N/A
Sweep test of existing antenna $6,730.00 $3,750.00 Updated to reflect actual costs to date. $3,750.00 N/A
UHF - High Power Top Mount (200-1000 kW), Four Station broadband panel antenna, elliptically or circularly polarized $1,090,000.00 $0.00 N/A $0.00 N/A

Components

Actual Information Description File Name
Adding a module to existing combiner (without antenna)

Component Description:
50% "balance" for aux combiner work. Supporting documentation is attached. This invoice has been paid.
Amount:
$4,941.00

Component Description:
50% "down payment" for aux combiner work. Supporting documentation is attached. This invoice has been paid.
Amount:
$4,941.00

Component Description:
40% "with order payment" for interim single channel VPT combiner system. Detailed cost breakdown and supporting documentation attached. This invoice has been paid.
Amount:
$40,130.93

Component Description:
10% "acceptance payment" for interim single channel VPT combiner system. Detailed cost breakdown and supporting documentation attached. This invoice has been paid.
Amount:
$10,032.74

Component Description:
50% "prior to ship payment" for interim single channel VPT combiner system. Detailed cost breakdown and supporting documentation attached. This invoice has been paid.
Amount:
$50,163.67
Sweep test of existing antenna

Component Description:
1/2 of cost of Radio Frequency Systems, Inc. proof of performance for 1WTC combiner and commissioning. Supporting documentation attached. This invoice has been paid.
Amount:
$3,750.00
UHF - High Power Top Mount (200-1000 kW), Four Station broadband panel antenna, elliptically or circularly polarized Information not provided.
Adding a module to existing combiner (without antenna)

Component Description:
50% "balance" for main combiner work. Supporting documentation is attached. This invoice has been paid.
Amount:
$4,941.00

Component Description:
50% "down payment" for main combiner work. Supporting documentation is attached. This invoice has been paid.
Amount:
$4,941.00

Component Description:
10% "acceptance payment" for primary single channel VPT combiner system. Detailed cost breakdown and supporting documentation attached. This invoice has been paid.
Amount:
$10,032.73

Component Description:
50% "prior to ship payment" for primary single channel VPT combiner system. Detailed cost breakdown and supporting documentation attached. This invoice has been paid.
Amount:
$50,163.67

Component Description:
40% "with order payment" for primary single channel VPT combiner system. Detailed cost breakdown and supporting documentation attached. This invoice has been paid.
Amount:
$40,130.94
Sweep test of existing antenna

Component Description:
1/2 of cost of Radio Frequency Systems, Inc. proof of performance for 1WTC combiner and commissioning. Supporting documentation attached. This invoice has been paid.
Amount:
$3,750.00
UHF - High Power Top Mount (200-1000 kW), Four Station broadband panel antenna, elliptically or circularly polarized Information not provided.

Cost Information

Back to Top

Transmission Line

Information not provided.

Cost Information

Back to Top

Tower Equipment and Rigging Costs

Where no predetermined cost estimate is available, any estimate provided will also become the predetermined cost (displayed in italics).
Description Predetermined
Cost Estimate
Estimated Cost Estimated Cost Justification Actual Cost Actual Cost Justification
Sub-total $881,320.00 $266,249.45 N/A $264,249.45 N/A
Total for all systems $6,398,219.81 $2,850,334.40 N/A $2,335,696.98 N/A
Primary Tower BTWR $460,320.00 $39,320.00 $37,320.00
Professional Engineering Services for the Removal of Exterior Systems $39,320.00 $39,320.00 Professional Design ENG Services for the Preparation and Submission of Applications and Permitting to the NYC Department of Buildings and the NYC Landmark Commission. Please see attached Advent Industrial Quote. $37,320.00 N/A
Complex Tower (includes, for example, those with candelabras and/or stacked antennas) $421,000.00 $0.00 N/A N/A N/A
Primary Tower B $421,000.00 $226,929.45 $226,929.45
Complex Tower (includes, for example, those with candelabras and/or stacked antennas) $421,000.00 $226,929.45 Please see Cover Letter for Equipment Removal from Empire and supporting documents. Actual cost significantly less than original estimate. $226,929.45 N/A

Components

Actual Information Description File Name
Professional Engineering Services for the Removal of Exterior Systems

Component Description:
20% final payment for ENG Services for permitting necessary for removal of exterior equipment from Empire State Building (net of non-removal costs). Per FCC guidance, detailed cost breakdown, explanation of variance, and supporting documentation attached.
Amount:
$5,864.00

Component Description:
20% final payment for ENG Services for permitting necessary for removal of exterior equipment from Empire State Building. Supporting documentation attached. This invoice has been paid.
Amount:
$7,864.00

Component Description:
30% progress payment for ENG services for permitting necessary for removal of exterior equipment from Empire State Building. Supporting documentation attached. This invoice has been paid.
Amount:
$11,796.00

Component Description:
50% deposit for ENG services for permitting necessary for removal of exterior equipment from Empire State Building. Supporting documentation attached. This invoice has been paid.
Amount:
$19,660.00

Component Description:
50% deposit for ENG services for permitting necessary for removal of exterior equipment from Empire State Building. Per FCC guidance, detailed cost breakdown, explanation of variance, and supporting documentation attached. This invoice has been paid.
Amount:
$19,660.00

Component Description:
30% progress payment for ENG services for permitting necessary for removal of exterior equipment from Empire State Building. Per FCC guidance, detailed cost breakdown, explanation of variance, and supporting documentation attached.
Amount:
$11,796.00
Complex Tower (includes, for example, those with candelabras and/or stacked antennas) Information not provided.
Complex Tower (includes, for example, those with candelabras and/or stacked antennas)

Component Description:
Cost charged by landlord to remove pre-repack equipment from Empire State Building tower. Supporting documentation and explanation of variance are attached. This invoice has been paid.
Amount:
$226,929.45

Cost Information

Back to Top

Outside Professional Services

Where no predetermined cost estimate is available, any estimate provided will also become the predetermined cost (displayed in italics).
Description Predetermined
Cost Estimate
Estimated Cost Estimated Cost Justification Actual Cost Actual Cost Justification
Sub-total $365,885.86 $436,770.66 N/A $166,113.36 N/A
Total for all systems $6,398,219.81 $2,850,334.40 N/A $2,335,696.98 N/A
Outside Professional Services $365,885.86 $436,770.66 $166,113.36
Commissioning of combiner $28,680.00 $28,680.00 See attached Radio Frequency System Invoices #27010375, #27010377, #7232195. $28,680.00 N/A
Engineering Services $137,370.86 $137,370.86 See attached Hanson Architects & Engineers Invoices #1061877, #1063493, #1062322, #1063471 $137,370.86 N/A
Installation Supervision $25,000.00 $25,000.00 N/A N/A N/A
RF Exposure Measurements $21,050.00 $20,000.00 N/A N/A N/A
Comprehensive coverage verification via field study, if needed $84,200.00 $80,000.00 N/A N/A N/A
Environmental Assessment, if triggered by NEPA Section 106 review or for certain structures over 450 feet $10,520.00 $0.00 N/A N/A N/A
NEPA Section 106 environmental review, if needed $6,310.00 $0.00 N/A N/A N/A
Attorney Fees - Prepare and File request for Special Temporary Authorization $7,360.00 $3,500.00 N/A $0.00 N/A
Attorney Fees - Negotiation of lease and other matters for shared locations $4,210.00 $74,646.90 Per FCC procedure, as the actual cost for this expense is greater than what was previously estimated, ION has updated the cost estimate to reflect our latest invoice. Please see Cooley #501527-146 for supporting documentation. $0.00 N/A
Attorney Fees -Prepare and File FCC Form 2100 (main), License to Cover Application $2,365.00 $2,250.00 N/A N/A N/A
Attorney Fees - Aux Antenna, prepare and File Form 2100 Construction Permit or License Application $4,210.00 $4,000.00 N/A N/A N/A
Attorney Fees - Prepare and File FCC Form 2100 (main), Construction Permit Application $5,260.00 $5,260.00 N/A $0.00 N/A
Prepare request for Special Temporary Authorization $4,100.00 $1,500.00 N/A N/A N/A
RF Consulting Engineer Fees- Aux Antenna: Prepare engineering section of FCC Form 2100, License to Cover Application $1,580.00 $1,500.00 N/A N/A N/A
Prepare engineering section of FCC Form 2100 (main), License to Cover Application $1,580.00 $1,500.00 N/A N/A N/A
RF Consulting Engineer Fees- Aux Antenna: Prepare engineering section of FCC Form 2100, Construction Permit Application $2,105.00 $2,000.00 N/A N/A N/A
Prepare engineering section of FCC Form 2100 (main), Construction Permit Application $3,155.00 $3,000.00 N/A N/A N/A
Perform engineering study for new channel assignment and antenna development $7,360.00 $7,000.00 N/A $62.50 N/A
Address transition timing and coordination issues w/ other stations and wireless $2,630.00 $2,500.00 N/A N/A N/A
Prepare and or review reimbursement form $2,630.00 $37,062.90 Per FCC procedure, as the actual cost for this expense is greater than what was previously estimated, ION has updated the cost estimate to reflect our latest invoice. Please see Cooley #501527-146 for supporting documentation. $0.00 N/A
FAA consultant, including cost of preparing FAA Form 7460 (Notice of Proposed Construction), if needed for height increase $2,105.00 $0.00 N/A N/A N/A
ASR modification (prepare FCC Form 854) $2,105.00 $0.00 N/A N/A N/A

Components

Actual Information Description File Name
Commissioning of combiner

Component Description:
50% "prior to ship payment" for commissioning of combiner. Detailed cost breakdown and supporting documentation attached. This invoice has been paid.
Amount:
$14,340.00

Component Description:
40% "with order payment" for commissioning of combiner. Detailed cost breakdown and supporting documentation attached. This invoice has been paid.
Amount:
$11,472.00

Component Description:
10% "acceptance payment" for commissioning of combiner. Detailed cost breakdown and supporting documentation attached. This invoice has been paid.
Amount:
$2,868.00
Engineering Services

Component Description:
Per FCC guidance, this invoice is being re-submitted a third time with cover letter. 20% Payment for Project Scope of Work (net of non-removal costs). Explanation of variance form and supporting documentation attached. This invoice has been paid.
Amount:
$8,096.00

Component Description:
Per RFI, invoice is being resubmitted with cover letter. 20% Payment for Design Coordination, Engineering & Construction Documents, Engineering Services during Construction Phase and Project Expenses. Supporting documentation attached.
Amount:
$19,378.17

Component Description:
80% Payment for Project Scope of Work (net of non-removal costs). Explanation of variance forms, and supporting documentation attached. This invoice has been paid.
Amount:
$32,384.00

Component Description:
Per FCC guidance, this invoice is being re-submitted a second time. 80% Payment for Project Scope of Work (net of non-removal costs). Cover letter, explanation of variance forms, and revised supporting documentation attached. This invoice has been paid.
Amount:
$32,384.00

Component Description:
80% payment for Project Scope of Work, Site Survey and Plans & Specifications for Vacating Empire State Building. Supporting documentation attached. This invoice has been paid.
Amount:
$36,800.00

Component Description:
Per FCC guidance, invoice is being resubmitted with cover letter. 80% Payment for Design Coordination, Engineering & Construction Documents, Engineering Services during Construction Phase and Project Expenses. Supporting documentation attached.
Amount:
$77,512.69

Component Description:
20% Payment for Design Coordination, Engineering & Construction Documents, Engineering Services during Construction Phase and Project Expenses. Per FCC guidance, explanation of variance and supporting documentation attached. This invoice has been paid.
Amount:
$19,378.17

Component Description:
80% Payment for Design Coordination, Engineering & Construction Documents, Engineering Services during Construction Phase and Project Expenses. Supporting documentation attached. This invoice has been paid.
Amount:
$77,512.69

Component Description:
20% Payment for Project Scope of Work, Site Survey and Plans & Specifications for Vacating Empire State Building. Supporting documentation attached. This invoice has been paid.
Amount:
$9,200.00
Installation Supervision Information not provided.
RF Exposure Measurements Information not provided.
Comprehensive coverage verification via field study, if needed Information not provided.
Environmental Assessment, if triggered by NEPA Section 106 review or for certain structures over 450 feet Information not provided.
NEPA Section 106 environmental review, if needed Information not provided.
Attorney Fees - Prepare and File request for Special Temporary Authorization

Component Description:
Cost of legal fees related to STA request. Supporting documentation is attached. This invoice has been paid.
Amount:
$2,289.60
Attorney Fees - Negotiation of lease and other matters for shared locations

Component Description:
Attorney fees for services rendered negotiating lease and other matters for shared New York City tower site of ION Media License Company, LLC, WPXN-TV. Hourly supporting documentation attached. This invoice has been paid.
Amount:
$74,646.90
Attorney Fees -Prepare and File FCC Form 2100 (main), License to Cover Application Information not provided.
Attorney Fees - Aux Antenna, prepare and File Form 2100 Construction Permit or License Application Information not provided.
Attorney Fees - Prepare and File FCC Form 2100 (main), Construction Permit Application

Component Description:
Cost of legal fees related to repack reimbursements. Supporting documentation is attached. This invoice has been paid.
Amount:
$2,916.00

Component Description:
Attorney fees for services rendered preparing and filing FCC Form 2100, Construction Permit Application of ION Media License Company, LLC, WPXN-TV. Hourly supporting documentation attached. This invoice has been paid.
Amount:
$14,359.30
Prepare request for Special Temporary Authorization Information not provided.
RF Consulting Engineer Fees- Aux Antenna: Prepare engineering section of FCC Form 2100, License to Cover Application Information not provided.
Prepare engineering section of FCC Form 2100 (main), License to Cover Application Information not provided.
RF Consulting Engineer Fees- Aux Antenna: Prepare engineering section of FCC Form 2100, Construction Permit Application Information not provided.
Prepare engineering section of FCC Form 2100 (main), Construction Permit Application Information not provided.
Perform engineering study for new channel assignment and antenna development

Component Description:
Cost of engineering study for new channel assignment. Supporting documentation is attached. This invoice has been paid.
Amount:
$62.50
Address transition timing and coordination issues w/ other stations and wireless Information not provided.
Prepare and or review reimbursement form

Component Description:
Attorney fees for preparing, reviewing and revising the Reimbursement Form (FCC Form 2100 Schedule 399) in connection with the expedited relocation from ESB to 1WTC as part of NYC television repack project of ION Media License Company, LLC, WPXN-TV.
Amount:
$37,062.90
FAA consultant, including cost of preparing FAA Form 7460 (Notice of Proposed Construction), if needed for height increase Information not provided.
ASR modification (prepare FCC Form 854) Information not provided.

Cost Information

Back to Top

Other Expenses

Where no predetermined cost estimate is available, any estimate provided will also become the predetermined cost (displayed in italics).
Description Predetermined
Cost Estimate
Estimated Cost Estimated Cost Justification Actual Cost Actual Cost Justification
Sub-total $123,139.00 $118,964.00 N/A $44,587.05 N/A
Total for all systems $6,398,219.81 $2,850,334.40 N/A $2,335,696.98 N/A
Other Expenses $123,139.00 $118,964.00 $44,587.05
Equipment Delivery and Handling Charges $21,949.00 $21,949.00 N/A $21,949.00 N/A
Non-zoning permits $25,000.00 $25,000.00 N/A $8,938.05 N/A
DTV Medical Facility Notification $11,550.00 $8,500.00 N/A $8,500.00 N/A
MVPD Notification of Channel Change $3,000.00 $3,000.00 N/A $3,000.00 N/A
Develop and air announcement of upcoming channel change $0.00 $0.00 The amount is yet to be determined (TBD) and ION will submit on-air announcement costs when finalized. N/A N/A
Equipment Storage $10,000.00 $10,000.00 N/A N/A N/A
Disposal Costs (for equipment and other waste, net of any salvage value) $25,000.00 $25,000.00 N/A N/A N/A
Local Zoning $25,000.00 $25,000.00 N/A $2,200.00 N/A
FCC Filing Fees - Special Temporary Authorization request $195.00 $190.00 N/A N/A N/A
FCC Filing Fees - Form 2100 license to cover application $335.00 $325.00 N/A N/A N/A
FCC Filing Fees - Form 2100 minor change CP application $1,110.00 $0.00 N/A N/A N/A

Components

Actual Information Description File Name
Equipment Delivery and Handling Charges

Component Description:
Cost for Administrative, Logistics, Dock Labor, Crate Modification Materials & Freight for Equipment Delivery of Mixed Components. Supporting documentation attached. This invoice has been paid.
Amount:
$1,869.00

Component Description:
Cost for Administrative, Logistics, Dock Labor, Freight for Equipment Delivery of Mixed Components Supporting documentation attached. This invoice has been paid.
Amount:
$1,180.00

Component Description:
Cost for Administrative, Logistics, Labor, & Freight for Equipment Delivery of Mixed Components. Supporting documentation attached. This invoice has been paid.
Amount:
$7,050.00

Component Description:
Cost of freight for RFS combiner module system. Detailed cost breakdown and supporting documentation attached. This invoice has been paid.
Amount:
$10,000.00

Component Description:
Cost for Administrative, Logistics, Dock Labor, Freight for Equipment Delivery of Mixed Components. Supporting documentation attached. This invoice has been paid.
Amount:
$1,850.00
Non-zoning permits

Component Description:
20% Payment for Tenant Alteration Application (TAA). IMPORTANT NOTE: TAA filing fees are not included in this invoice. Detailed cost breakdown and supporting documentation attached. This invoice has been paid.
Amount:
$1,798.41

Component Description:
80% Payment for Tenant Alteration Application (TAA) plus TAA Filing Fee for the Port Authority of NY/NJ. Cost breakdown and supporting documentation attached. This invoice has been paid.
Amount:
$21,193.64

Component Description:
Per RFI, invoice is being resubmitted with cover letter. 20% Payment for Tenant Alteration Application (TAA). IMPORTANT NOTE: TAA filing fees are not included in this invoice. Detailed cost breakdown and supporting documentation attached.
Amount:
$1,798.41

Component Description:
Per FCC guidance, invoice is being resubmitted with cover letter. 80% Payment for Tenant Alteration Application (TAA). IMPORTANT NOTE: TAA filing fees are not included in this invoice. Detailed cost breakdown and supporting documentation attached.
Amount:
$7,139.64
DTV Medical Facility Notification

Component Description:
Cost of medical notifications for channel change. Supporting documentation is attached. This invoice has been paid.
Amount:
$8,500.00
MVPD Notification of Channel Change

Component Description:
Cost of MVPD notifications for channel change. Supporting documentation is attached. This invoice has been paid.
Amount:
$3,000.00
Develop and air announcement of upcoming channel change Information not provided.
Equipment Storage Information not provided.
Disposal Costs (for equipment and other waste, net of any salvage value) Information not provided.
Local Zoning

Component Description:
Cost of inspection and filing fees for city requirements. Supporting documentation is attached. This invoice has been paid.
Amount:
$2,200.00
FCC Filing Fees - Special Temporary Authorization request Information not provided.
FCC Filing Fees - Form 2100 license to cover application Information not provided.
FCC Filing Fees - Form 2100 minor change CP application Information not provided.

Cost Information

Back to Top

Grand Total

Predetermined
Cost Estimate
Estimated Cost Actual Cost
Total for all systems $6,398,219.81 $2,850,334.40 $2,335,696.98

Reimbursement Status

Back to Top
Question Response
The facility has ceased operating on its pre-auction channel. Yes
Construction of final facilities or all necessary modifications are complete. No
All receipts for reimbursement have been submitted no further costs are expected to be incurred. Note this will lock the Form 399 from further editing and begin close-out procedures with the Fund Administrator. No

Certification

Back to Top
Section Question Response
Submission of Estimated Expenses Statements

WILLFUL FALSE STATEMENTS ON THIS FORM ARE PUNISHABLE BY FINE AND/OR IMPRISONMENT (U.S. CODE, TITLE 18, SECTION 1001), AND/OR REVOCATION OF ANY STATION LICENSE OR CONSTRUCTION PERMIT (U.S. CODE, TITLE 47, SECTION 312(a)(1), AND/OR FORFEITURE (U.S. CODE, TITLE 47, SECTION 503), AND ANY FALSE STATEMENTS COULD SUBJECT THIS ENTITY TO LIABILITY UNDER THE FALSE CLAIMS ACT.

  1. The Authorized Person signing below certifies that he/she is authorized to submit this TV Broadcaster Relocation Fund Reimbursement Form on behalf of the above-named entity.

  2. The above-named entity acknowledges that all certifications and attached documentation are considered material representations.

  3. The above-named entity acknowledges the submission of the information herein creates no obligation on the part of the government to pay any amount.

  4. The above-named entity certifies that the equipment and services paid for with money from the TV Broadcaster Relocation Fund are necessary to change channels (broadcasters) or to continue to carry the signal of a broadcaster that changes channels (MVPD).

  5. The above-named entity certifies that all payments from the TV Broadcaster Relocation Fund (Fund) received by the entity listed on this form will be used only for expenses that are eligible for reimbursement from the Fund.

  6. The above-named entity certifies that it will maintain and provide to the Commission detailed records, including receipts, of all costs eligible for reimbursement actually incurred.

  7. The above-named entity acknowledges that overpayments or payments in error must be promptly refunded to the Commission.

  8. The above-named entity certifies that it is in full compliance with all statutes, rules, regulations and governmental requirements for which compliance is a pre-requisite for obtaining the payments herein requested.

I declare, under penalty of perjury, that I am an authorized representative of the above-named applicant for the Authorization(s) specified above.

Mario Vasquez

Vice President - Finance, Operations


03/30/2021

Certification

Back to Top
Section Question Response
Submission of Actual Cost Documentation Statements

WILLFUL FALSE, FRAUDULENT, OR FICTITIOUS STATEMENTS ON THIS FORM ARE PUNISHABLE BY FINE AND/OR IMPRISIONMENT (U.S. CODE, TITLE 18, SECTION 1001), AND/OR REVOCATION OF ANY STATION LICENSE OR CONSTRUCTION PERMIT (U.S. CODE, TITLE 47, SECTION 312(a)(1), AND/OR FORFEITURE (U.S. CODE, TITLE 47, SECTION 503), AND ANY FALSE AND/OR FRAUDULENT STATEMENTS COULD SUBJECT THIS ENTITY TO LIABILITY UNDER THE FALSE CLAIMS ACT (U.S. CODE, TITLE 31, SECTIONS 3729-3733).

  1. The Authorized Person signing below certifies and represents that he/she is authorized to submit this TV Broadcaster Relocation Fund Reimbursement Form on behalf of the above-named entity.

  2. The above-named entity certifies that the statements in this form and attached documentation are true, complete, and correct.

  3. The above-named entity acknowledges that all certifications and attached documentation are considered material representations.

  4. The above-named entity acknowledges the submission of the information herein creates no obligation on the part of the government to pay any amount.

  5. The above-named entity certifies that the equipment and services paid for with money from the TV Broadcaster Relocation Fund are necessary to change channels (full power and Class A stations) and/or otherwise modify a television station’s facility as a result of the spectrum repack (LPTV/TV Translator stations); or to minimize service disruption resulting from a repacked television station (FM stations); or to continue to carry the signal of a broadcaster that changes channels (MVPD) .

  6. The above-named entity certifies that all payments from the TV Broadcaster Relocation Fund (Fund) received by the entity listed on this form will be used only for expenses that are eligible for reimbursement from the Fund.

  7. The above-named entity certifies that the cost information/documents submitted reflect costs actually incurred.

  8. The above-named entity acknowledges that overpayments or payments in error must be promptly refunded to the Commission.

  9. The above-named entity certifies that it is in full compliance with all statutes, rules, regulations and governmental requirements for which compliance is a prerequisite for obtaining the payments herein requested.

I declare, under penalty of perjury, that I am an authorized representative of the above-named applicant for the Authorization(s) specified above.

Mario Vasquez

Vice President - Finance, Operations


03/30/2021

Attachments

Back to Top