Go to the Federal Communications Commission homepage at www.fcc.gov

FCC Form 399: Reimbursement Request

Approved by OMB 3060-1178
Go to the Federal Communications Commission homepage at www.fcc.gov

(REFERENCE COPY - Not for submission) FCC Form 399: Reimbursement Request

Facility ID:
71357
Service:
DTV
Call Sign:
WDSU
Channel:
19 (UHF)
File Number:
0000026830
FRN:
0001769256
Date Submitted:
08/18/2019

Applicant Information

Back to Top

Applicant Name, Type, and Contact Information

Applicant Address Phone Email Applicant Type

NEW ORLEANS HEARST TELEVISION INC.

Doing Business As: NEW ORLEANS HEARST TELEVISION INC.

P.O. BOX 1800

RALEIGH, NC 27602

United States

+1 (919) 839-0300 mprak@brookspierce.com Corporation

Reimbursement Contact Information

Reimbursement Contact Name and Information

Applicant Address Phone Email

[Confidential]

 

 

 


Preparer Contact Information

Back to Top

Preparer Contact Name and Information

Applicant Address Phone Email

The Preparer is same as the reimbursement contact.

 

 

 

Broadcaster Information and Transition Plan

Back to Top
Question Response
Will the station be sharing equipment with another broadcast television station or stations (e.g., a shared antenna, co-location on a tower, use of the same transmitter room, multiple transmitters feeding a combiner, etc.)? If yes, enter the facility ID's of the other stations and click 'prefill' to download those stations' licensing information. Yes
Briefly describe transition plan see attached transition plan document

Transmitters

Back to Top
Section Question Response
Transmitter Related Expenses Do you have transmitter related expenses? Yes

Primary Transmitter

Back to Top

Existing Transmitter Information

Section Question Response
Existing Transmitter Description Type of change Purchase New
Use Primary (Main)
Description of Use N/A
Ownership Owned
Owner N/A
Site N/A
Is this transmitter currently shared with another station? No
Is this transmitter currently in operating condition? Yes
Existing Transmitter Manufacturer and Type Manufacturer
Model Sigma CD3260P2
Year 2008
Type Inductive Output Tube
IOT Power Type Two
Power Capacity 60 kW

Primary Transmitter

Back to Top

New Transmitter Costs

Section Question Response
New Transmitter Use Primary (Main)
Change Type Purchase New
Is this a request for upgraded equipment? Yes
Manufacturer
Model ULXTE-40
Transmitter Type Solid State
Solid State Cooling Liquid Cooled
Solid State Power capacity 25.3 kW
Justification for New Transmitter Existing IOT transmitter cannot be converted to post-transition channel, see GatesAir EOL and HTV IOT to Solid-State Justification statements. An IOT replacement is more expensive than proposed SS transmitter. See attached Comark IOT Transmitter quote.

Primary Transmitter

Back to Top

Other Transmitter Costs

Section Question Response
Electrical Service Service Entrance (3 phases 800A 208V) No
Switchgear (industrial 800 amp) No
Transformer (480V) No
Power N/A
Rigid Conduit and Wiring No
Size N/A
Length N/A
Other Electrical Service Yes
Description see attached quote for transmitter electrical service
HVAC Service Does the replacement transmitter require HVAC Service? No
Type N/A
Size N/A
Other Size N/A
Transmitter Building Addition/Modification or Leasehold Improvement Does the Transmitter Building require an addition, modification, other leashold improvement? No
Size N/A
Channel 14 Costs Is an RF Consulting Engineer needed? N/A
Is a channel 14 Mask Filer needed? N/A
Is additional field engineering time needed? N/A
Number of Days N/A

Primary Transmitter

Back to Top

Other Transmitter Cost Not Listed

Name Description

Sales Tax

transmitter sales tax

Change Order

required transmitter configuration changes

Shipping

transmitter shipping

Remote Control upgrade

Transmitter Remote Control equipment for repack transmitter

Transmitter installation incidentals

miscellaneous items needed for transmitter installation

combiner installation

cost to install new antenna combiner for the three stations sharing both main and backup antennas

Electrical Accessories

Manufacturer required surge protection & voltage conversion

RF Accessories

Additional RF components required for transmitter operation

Antennas

Back to Top
Section Question Response
Antenna Related Expenses Do you have antenna related expenses? Yes

Primary Antenna

Back to Top

Existing Antenna Information

Section Question Response
Existing Antenna Description Type of change Retune Existing
Antenna Use Primary (Main)
Description of Use N/A
Ownership Owned
Owner N/A
Site N/A
Is the existing antenna shared with another station or stations? Yes
Is the existing antenna directional? Yes
Is antenna in operating condition? Yes
Is antenna located on or in close proximity to an antenna farm? No
Existing Antenna Manufacturer and Type Class Full Power
Mounting Top Mount
Antenna position in stack Not in Stack
Polarization Horizontal
Type Broadband Panel
Number of Stations Supported 3
Number of Panels 23
Design power capacity in use 66.0 %
Lower Limit 470.00 MHz
Upper Limit 698.00 MHz
Other Antenna Type N/A
ERP: 1000.0 kW
Manufacturer Dielectric
Model TUF-C4SP-10/32U
Year 2008

Facility ID's and Call Signs of all stations with whom the antenna is shared.

Facility ID Call Sign
54280 WNOL-TV
72119 WGNO

Primary Antenna

Back to Top

Adjustment to Existing Antenna

Section Question Response
Sweep Test of Existing Antenna Do you need a sweep test of existing antenna? Yes

Primary Antenna

Back to Top

Other Antenna Costs

Section Question Response
Combiner for Shared Antenna Do you need a Combiner for a Shared Antenna? Yes
Type New
Number of channels supported 3
Frequencies of channels supported RF channel
Frequency N/A

Enter a list of RF channel numbers.

RF Channel Number
26
15
19

Primary Antenna

Back to Top

Other Antenna Cost Not Listed

Information not provided.

Auxiliary Antenna

Back to Top

Existing Antenna Information

Section Question Response
Existing Antenna Description Type of change Retune Existing
Antenna Use Auxiliary (Backup)
Description of Use backup to main antenna
Ownership Owned
Owner N/A
Site N/A
Is the existing antenna shared with another station or stations? Yes
Is the existing antenna directional? Yes
Is antenna in operating condition? Yes
Is antenna located on or in close proximity to an antenna farm? No
Existing Antenna Manufacturer and Type Class Full Power
Mounting Side Mount
Antenna position in stack Not in Stack
Polarization Horizontal
Type Other
Number of Stations Supported N/A
Number of Panels N/A
Design power capacity in use N/A
Lower Limit N/A
Upper Limit N/A
Other Antenna Type broadband slot cavity
ERP: 780.0 kW
Manufacturer RFS
Model RD32A-HP
Year 2008

Facility ID's and Call Signs of all stations with whom the antenna is shared.

Facility ID Call Sign
54280 WNOL-TV
72119 WGNO

Auxiliary Antenna

Back to Top

Adjustment to Existing Antenna

Section Question Response
Sweep Test of Existing Antenna Do you need a sweep test of existing antenna? Yes

Auxiliary Antenna

Back to Top

Other Antenna Costs

Section Question Response
Combiner for Shared Antenna Do you need a Combiner for a Shared Antenna? No
Type
Number of channels supported N/A
Frequencies of channels supported N/A
Frequency

Auxiliary Antenna

Back to Top

Other Antenna Cost Not Listed

Information not provided.

Transmission Line

Back to Top
Section Question Response
Transmission Line Related Expenses Do you have transmission line related expenses? No

Tower Equipment And Rigging Costs

Back to Top
Section Question Response
Tower Equipment or Rigging Costs Changes Do you have tower equipment or rigging costs changes? No

Outside Professional Services Costs

Back to Top
Section Question Response
Outside Project Management Services Do you require outside project management services? Yes
Number of Hours 200
Explanation Need outside RF experience to assist with transition planning and execution.
Outside RF consulting Engineering Services Perform engineering study for new channel assignment and antenna development Yes
Prepare engineering section of Form FCC Construction Permit Application Yes
For Auxiliary Facility Yes
For Main Facility Yes
Prepare engineering section of Form FCC License to Cover Application Yes
For Auxiliary Facility Yes
For Main Facility Yes
Prepare request for Special Temporary Authority Yes
Quantity 1
Do you have Distributed Transmission System engineering services? N/A
Critical Facility N/A
Terrain-Shielded Facility N/A
Attorney and Other Outside Consulting Services Prepare and file Form FCC Construction Permit Application Yes
For Auxiliary Facility Yes
For Main Facility Yes
Prepare and file Form FCC License to Cover Application Yes
For Auxiliary Facility Yes
For Main Facility Yes
Prepare request for Special Temporary Authority Yes
Quantity 1
NEPA Section 106 environmental review No
Environmental Assessment No
ASR Modification No
FAA Consultation (including preparation of FAA Form 7460) No
Negotiation of Lease and other Matter for Shared Locations No
Prepare or Review FCC Form 399 for Reimbursement Yes
Address transition timing and coordination issues w/ other stations and wireless providers Yes
RF Field Engineering Services Comprehensive coverage verification via field study No
RF exposure measurements No
Additional Field Engineering Service No
Number of Days N/A
Justification N/A

Outside Professional Services Costs

Back to Top

Other Professional Services Expenses Not Listed

Name Description

Transmitter Site Survey

Transmitter planning survey & transmitter building drawings

Non-Catalog legal expenses

Non-Catalog expenses for legal advice and services, including financial/reimbursement review, transition reporting, transition procedures, and other transition-related issues

Other Expenses

Back to Top
Section Question Response
AM Pattern Disturbance Is an Impact Study needed? No
Is Remediation needed? No
Facility Expenses Name N/A
Other Distributed Transmission System Expenses Not listed N/A
Name N/A
Is Notification of a Medical Facility required as a result of DTV broadcasting? Yes
Permit and Filing Costs Local Zoning No
Non-zoning permits No
BLM or NFS Coordination No
FCC Construction Permit Minor Change Yes
FCC License to Cover Application Yes
FCC Special Temporary Authority Application No
Other Miscellaneous Expenses Does this relocation require paying Disposal Costs (for equipment and other waste, net of any salvage value)? No
Does this relocation require Equipment Delivery or Handling Charges not otherwise included in individual item costs? No
Does this relocation require Equipment Storage? No
Does this relocation require the Development and Airing of an Announcement regarding an upcoming channel change? Yes
Does this relocation require MVPD Notification of a Channel Change? Yes

Other Expenses

Back to Top

Other Expenses Not Listed

Name Description

Contract Labor

labor directly related to the station channel change

Cost Information

Back to Top

Transmitters

Where no predetermined cost estimate is available, any estimate provided will also become the predetermined cost (displayed in italics).
Description Predetermined
Cost Estimate
Estimated Cost Estimated Cost Justification Actual Cost Actual Cost Justification
Sub-total $1,323,823.92 $1,239,118.10 N/A $1,061,393.01 N/A
Total for all systems $1,553,993.38 $1,451,578.56 N/A $1,109,485.11 N/A
Primary Transmitter ULXTE-40 $1,323,823.92 $1,239,118.10 $1,061,393.01
RF Accessories $163,607.38 $163,607.38 RF components required for transmitter and connection/switching to combiner and antenna systems $90,305.08 N/A
Electrical Accessories $7,812.49 $7,812.49 Required transmitter electrical components. See GatesAir quote. $7,812.49 N/A
combiner installation $5,853.90 $5,853.90 cost to install antenna combiner per attached GatesAir transmitter quote N/A N/A
Transmitter installation incidentals $6,000.00 $6,000.00 estimate for equipment rentals and other items needed for transmitter installation $5,409.77 N/A
Remote Control upgrade $2,354.39 $2,354.39 Remote control changes required for repack transmitter $2,354.39 N/A
Shipping $11,000.00 $11,000.00 See GatesAir quote N/A N/A
Change Order $405.76 $405.76 transmitter hardware changes $405.76 N/A
Other Electrical Service: see attached quote for transmitter electrical service $74,937.00 $74,937.00 Electrical service to install replacement transmitter. $74,937.00 N/A
UHF - Liquid Cooled Solid State Transmitter 21 - 31 kW $947,000.00 $862,294.18 GatesAir quote sections A, B & E. This is the transmitter, mask filter, installation and proof per the FCC "transmitter" definition. Plus additional plumbing installation $802,532.53 N/A
Sales Tax $104,853.00 $104,853.00 transmitter sales tax per attached GatesAir quote $77,635.99 N/A

Components

Actual Information Description File Name
RF Accessories

Component Description:
WDSU RF accessories less manifold combiner
Amount:
$90,305.08
Electrical Accessories

Component Description:
WDSU transmitter electrical accessories
Amount:
$7,812.49
combiner installation Information not provided.
Transmitter installation incidentals

Component Description:
WDSU equipment rental 1
Amount:
$2,088.46

Component Description:
WDSU equipment rental 3 rev
Amount:
$347.77

Component Description:
WDSU equipment rental 4 rev
Amount:
$561.53

Component Description:
WDSU equipment rental 2
Amount:
$2,412.01
Remote Control upgrade

Component Description:
Repack transmitter remote control equipment
Amount:
$2,354.39
Shipping Information not provided.
Change Order

Component Description:
WDSU transmitter change order 1 hardware changes only. Services on CO not included.
Amount:
$405.76
Other Electrical Service: see attached quote for transmitter electrical service

Component Description:
WDSU transmitter electrical installation 1
Amount:
$10,812.50

Component Description:
WDSU transmitter electrical installation 6
Amount:
$1,873.00

Component Description:
WDSU transmitter electrical installation 4
Amount:
$12,540.00

Component Description:
WDSU transmitter electrical installation 5
Amount:
$9,042.00

Component Description:
WDSU transmitter electrical installation 7
Amount:
$2,027.00

Component Description:
WDSU transmitter electrical installation 3
Amount:
$12,500.00

Component Description:
WDSU transmitter electrical installation 2
Amount:
$26,142.50
UHF - Liquid Cooled Solid State Transmitter 21 - 31 kW

Component Description:
Transmitter 1st deposit
Amount:
$105,296.63

Component Description:
WDSU transmitter plumbing installation
Amount:
$80,000.00

Component Description:
WDSU main transmitter on delivery invoice (FCC transmitter definition includes transmitter and mask filter)
Amount:
$72,593.53

Component Description:
Transmitter 2nd deposit
Amount:
$215,264.19

Component Description:
WDSU transmitter prior to ship
Amount:
$329,378.18
Sales Tax

Component Description:
WDSU transmitter tax 1
Amount:
$77,635.99

Cost Information

Back to Top

Antennas

Where no predetermined cost estimate is available, any estimate provided will also become the predetermined cost (displayed in italics).
Description Predetermined
Cost Estimate
Estimated Cost Estimated Cost Justification Actual Cost Actual Cost Justification
Sub-total $97,660.00 $91,956.00 N/A $0.00 N/A
Total for all systems $1,553,993.38 $1,451,578.56 N/A $1,109,485.11 N/A
Primary Antenna TUF-C4SP-10/32U $90,930.00 $85,556.00 $0.00
Sweep test of existing antenna $6,730.00 $6,400.00 N/A N/A N/A
New combiner, cost per channel (without antenna) $84,200.00 $79,156.00 Combiner and installation from GatesAir quote. This is the total cost of the 3 channel combiner, not the per channel cost. I don't see a provision in this form to multiply this figure by the number of channels. N/A N/A
Auxiliary Antenna RD32A-HP $6,730.00 $6,400.00 $0.00
Sweep test of existing antenna $6,730.00 $6,400.00 N/A N/A N/A

Components

Information not provided.

Cost Information

Back to Top

Transmission Line

Information not provided.

Cost Information

Back to Top

Tower Equipment and Rigging Costs

Information not provided.

Cost Information

Back to Top

Outside Professional Services

Where no predetermined cost estimate is available, any estimate provided will also become the predetermined cost (displayed in italics).
Description Predetermined
Cost Estimate
Estimated Cost Estimated Cost Justification Actual Cost Actual Cost Justification
Sub-total $110,805.00 $99,400.00 N/A $43,882.64 N/A
Total for all systems $1,553,993.38 $1,451,578.56 N/A $1,109,485.11 N/A
Outside Professional Services $110,805.00 $99,400.00 $43,882.64
Non-Catalog legal expenses $20,000.00 $20,000.00 Non-Catalog expenses for legal advice and services, including financial/reimbursement review, transition reporting, transition procedures, and other transition-related issues $6,176.72 N/A
Transmitter Site Survey $20,600.00 $20,600.00 Transmitter planning survey & transmitter building drawings. Quote attached $20,600.00 N/A
Attorney Fees - Prepare and File request for Special Temporary Authorization $3,680.00 $3,500.00 N/A N/A N/A
Attorney Fees -Prepare and File FCC Form 2100 (main), License to Cover Application $2,365.00 $2,250.00 N/A N/A N/A
Attorney Fees - Aux Antenna, prepare and File Form 2100 Construction Permit or License Application $4,210.00 $4,000.00 N/A N/A N/A
Attorney Fees - Prepare and File FCC Form 2100 (main), Construction Permit Application $5,260.00 $5,000.00 N/A $1,735.43 N/A
RF Consulting Engineer Fees- Aux Antenna: Prepare engineering section of FCC Form 2100, License to Cover Application $1,580.00 $1,500.00 N/A N/A N/A
Prepare engineering section of FCC Form 2100 (main), License to Cover Application $1,580.00 $1,500.00 N/A N/A N/A
RF Consulting Engineer Fees- Aux Antenna: Prepare engineering section of FCC Form 2100, Construction Permit Application $2,105.00 $2,050.00 N/A $1,450.00 N/A
Prepare engineering section of FCC Form 2100 (main), Construction Permit Application $3,155.00 $3,000.00 N/A $1,875.00 N/A
Perform engineering study for new channel assignment and antenna development $7,360.00 $7,000.00 N/A $1,150.00 N/A
Address transition timing and coordination issues w/ other stations and wireless $2,630.00 $2,500.00 N/A N/A N/A
Prepare and or review reimbursement form $2,630.00 $2,500.00 N/A $1,247.16 N/A
Project management of the transition $31,600.00 $22,500.00 N/A $9,648.33 N/A
Prepare request for Special Temporary Authorization $2,050.00 $1,500.00 N/A N/A N/A

Components

Actual Information Description File Name
Non-Catalog legal expenses

Component Description:
WDSU non-catalog legal 2
Amount:
$3,690.02

Component Description:
WDSU non-catalog legal 1
Amount:
$2,486.70
Transmitter Site Survey

Component Description:
WDSU Field Service GatesAir, 6-30-2016, $20,600
Amount:
$20,600.00
Attorney Fees - Prepare and File request for Special Temporary Authorization Information not provided.
Attorney Fees -Prepare and File FCC Form 2100 (main), License to Cover Application Information not provided.
Attorney Fees - Aux Antenna, prepare and File Form 2100 Construction Permit or License Application Information not provided.
Attorney Fees - Prepare and File FCC Form 2100 (main), Construction Permit Application

Component Description:
WDSU Prepare and File FCC Form 2100, Construction Permit Application
Amount:
$680.90

Component Description:
WDSU Prepare and File FCC Form 2100, Construction Permit Application 2
Amount:
$1,054.53
RF Consulting Engineer Fees- Aux Antenna: Prepare engineering section of FCC Form 2100, License to Cover Application Information not provided.
Prepare engineering section of FCC Form 2100 (main), License to Cover Application Information not provided.
RF Consulting Engineer Fees- Aux Antenna: Prepare engineering section of FCC Form 2100, Construction Permit Application

Component Description:
WDSU RF consulting for auxiliary antenna construction permit
Amount:
$1,450.00
Prepare engineering section of FCC Form 2100 (main), Construction Permit Application

Component Description:
Prepare engineering section of FCC Form 2100, Construction Permit Application
Amount:
$1,875.00
Perform engineering study for new channel assignment and antenna development

Component Description:
WDSU engineering study for new channel assignment
Amount:
$1,150.00
Address transition timing and coordination issues w/ other stations and wireless Information not provided.
Prepare and or review reimbursement form

Component Description:
WDSU Prepare and/or review reimbursement Form 399
Amount:
$947.10

Component Description:
WDSU Prepare and/or review reimbursement Form 399 2
Amount:
$300.06
Project management of the transition

Component Description:
WDSU Marsand project consulting
Amount:
$1,894.76

Component Description:
WDSU TI Digital project management
Amount:
$210.00

Component Description:
WDSU project management 4 rev 1
Amount:
$150.00

Component Description:
WDSU Kube Project Management/Consulting 3
Amount:
$3,303.70

Component Description:
WDSU project management 2 rev 1
Amount:
$297.50

Component Description:
WDSU Kube Project Management/Consulting 2
Amount:
$1,357.99

Component Description:
WDSU: Kube Project Management/Consulting 1
Amount:
$75.00

Component Description:
WDSU project management 1. Invoice total less unsupported travel expenses.
Amount:
$2,359.38
Prepare request for Special Temporary Authorization Information not provided.

Cost Information

Back to Top

Other Expenses

Where no predetermined cost estimate is available, any estimate provided will also become the predetermined cost (displayed in italics).
Description Predetermined
Cost Estimate
Estimated Cost Estimated Cost Justification Actual Cost Actual Cost Justification
Sub-total $21,704.46 $21,104.46 N/A $4,209.46 N/A
Total for all systems $1,553,993.38 $1,451,578.56 N/A $1,109,485.11 N/A
Other Expenses $21,704.46 $21,104.46 $4,209.46
Contract Labor $4,209.46 $4,209.46 accounting labor directly related to the Spectrum Repack project $4,209.46 N/A
MVPD Notification of Channel Change $2,500.00 $2,500.00 Legal council assistance in MVPD notification N/A N/A
Develop and air announcement of upcoming channel change $2,000.00 $2,000.00 Attorney fees to ensure compliance with FCC requirement N/A N/A
FCC Filing Fees - Form 2100 license to cover application $335.00 $325.00 N/A N/A N/A
FCC Filing Fees - Form 2100 minor change CP application $1,110.00 $1,070.00 N/A N/A N/A
DTV Medical Facility Notification $11,550.00 $11,000.00 N/A N/A N/A

Components

Actual Information Description File Name
Contract Labor

Component Description:
WDSU accounting labor
Amount:
$4,209.46
MVPD Notification of Channel Change Information not provided.
Develop and air announcement of upcoming channel change Information not provided.
FCC Filing Fees - Form 2100 license to cover application Information not provided.
FCC Filing Fees - Form 2100 minor change CP application Information not provided.
DTV Medical Facility Notification Information not provided.

Cost Information

Back to Top

Grand Total

Predetermined
Cost Estimate
Estimated Cost Actual Cost
Total for all systems $1,553,993.38 $1,451,578.56 $1,109,485.11

Reimbursement Status

Back to Top
Question Response
The facility has ceased operating on its pre-auction channel. No
Construction of final facilities or all necessary modifications are complete. No
All receipts for reimbursement have been submitted no further costs are expected to be incurred. Note this will lock the Form 399 from further editing and begin close-out procedures with the Fund Administrator. No

Attachments