Approved by OMB 3060-0027
September 2014
Go to the Federal Communications Commission homepage at www.fcc.gov

(REFERENCE COPY - Not for submission) Minor Modification of Full Power AM Construction Permit (301-AM)

File Number:
BMP-20071121ACX
Submit Date:
11/21/2007
Lead Call Sign:
KMES
FRN:
0017954686
Service:
Full Power AM
Purpose:
Minor Modification
Status:
Granted
Status Date:
03/13/2008
Filing Status:
Inactive


General Information

Section Question Response
Attachments Are attachments (other than associated schedules) being filed with this application?

Fees, Waivers, and Exemptions

Section Question Response
Fees Is the applicant exempt from FCC application Fees? No
Indicate reason for fee exemption:
Is the applicant exempt from FCC regulatory Fees?
Waivers Does this filing request a waiver of the Commission's rule(s)?
Total number of rule sections involved in this waiver request:

Applicant Information

Back to Top

Applicant Name, Type, and Contact Information

Applicant Address Phone Email Applicant Type

KLO BROADCASTING CO.

Applicant

Doing Business As: KLO BROADCASTING CO.

257 E. 200 SOUTH, SUITE 400

SALT LAKE CITY, UT 84111

United States

+1 (801) 364-9836

Company

Contact Representatives (2)

Back to Top
Contact Name Address Phone Email Contact Type

DONALD L. MARKLEY

CONSULTING ENGINEER

D. L. MARKLEY & ASSOCIATES, INC.

2104 WEST MOSS AVENUE

PEORIA, IL 61604

United States

+1 (309) 673-7511

DLM@DLMARKLEY.COM

Technical Representative

BRENDAN HOLLAND

DAVIS WRIGHT TREMAINE LLP

1919 PENNSYLVANIA AVE., NW

SUITE 200

WASHINGTON, DC 20006

United States

+1 (202) 973-4200

BRENDANHOLLAND@DWT.COM

Legal Representative

Attributable Interest

Back to Top
Section Question Response
Multiple Ownership Is the applicant or any party to the application the holder of an attributable radio joint sales agreement or an attributable radio time brokerage agreement in the same market as the station subject to this application?
Applicant certifies that the proposed facility complies with the Commission's multiple ownership rules.
Applicant certifies that the proposed facility: (a) does not present an issue under the Commission's policies relating to media interests of immediate family members; (b) complies with the Commission's policies relating to future ownership interests; (c) complies with the Commission's restrictions relating to the insulation and non-participation of non-party investors and creditors
Does the Applicant claim status as an "eligible entity," that is, an entity that qualifies as a small business under the Small Business Administration's size standards for its industry grouping (as set forth in 13 C.F.R. § 121-201), and holds: (a) 30 percent or more of the stock or partnership interests and more than 50 percent of the voting power of the corporation or partnership that will own the media outlet; or (b) 15 percent or more of the stock or partnership interests and more than 50 percent of the voting power of the corporation or partnership that will own the media outlet, provided that no other person or entity owns or controls more than 25 percent of the outstanding stock or partnership interests; or (c) more than 50 percent of the voting power of the corporation that will own the media outlet (if such corporation is a publicly traded company)?

Legal Certifications

Back to Top
Section Question Response
Character Issues Applicant certifies that neither applicant nor any party to the application has or had any interest in, or connection with: (a) any broadcast application in any proceeding where character issues were left in unresolved or were resolved adversely against the applicant or party to the application; or (b) any pending broadcast application in which character issues have been raised.
Adverse Findings Applicant certifies that, with respect to the applicant and any party to the application, and any non-party equity owner in the applicant, no adverse finding has been made, nor has an adverse final action been taken by any court or administrative body in a civil or criminal proceeding brought under the provisions of any law related to the following: any felony; mass media-related antitrust or unfair competition; fraudulent statements to another governmental unit; or discrimination.
Local Public Notice Applicant certifies that it has or will comply with the public notice requirements of 47 C.F.R. Section 73.3580.

Frequency and Facility Information

Back to Top
Section Question Response
Proposed Community of License State Utah
City Ogden
Facility Information Frequency 1430
Service Type Main
Facility Type Commercial
Class B
Modes/Hour of Operation Modes/Hour of Operation Daytime, NightTime

Antenna Summary Data

Back to Top

Directional Antenna Data - Daytime

Section Question Response
Parameters Power 25.000
Latitude 41° 2` 48.8N
Longitude 112° 1` 39.8W
Theoretical RMS 1834.779
Standard RMS 1927.233
Specified Q
Augmentation Augmentation N
Augmentation RMS
Augmentation Table
Central Azimuth (degrees) Span (degrees) Radiation at Central Azimuth (mV/m)
Site Plat and Tower Sketch Attach an antenna site plat and a tower sketch. The antenna site plat should clearly show the following items: Boundary lines, roads, railroads, other obstructions, and the ground system or counterpoise. Number and dimensions of ground radials or height and dimensions of counterpoise. Spacing and orientation of each element in the array with respect to true north. A scale in meters. The tower sketch should include site elevation, radiator height above base insulator, tower height above ground level, overall tower height above ground without obstruction lighting, and overall height above ground with obstruction lighting.

Directional Antenna : Tower - 1

Section Question Response
ASR Number Do you have an FCC Antenna Structure Registration (ASR) Number? Yes
ASR Number 1235889
Parameters Overall height above ground (including obstruction lighting) 87.8
Height of radiator above base insulator, or above base, if grounded 86.5
Electrical height of radiator 148.5
Field Ratio 0.344
Phase 18.9
Spacing 0
Tower Orientation 0
Tower Reference Switch 0
Is the tower toploaded, sectionalized, or neither? Neither
Tower Parameters A
B
C
D

Directional Antenna : Tower - 2

Section Question Response
ASR Number Do you have an FCC Antenna Structure Registration (ASR) Number? Yes
ASR Number 1235890
Parameters Overall height above ground (including obstruction lighting) 109.7
Height of radiator above base insulator, or above base, if grounded 108.6
Electrical height of radiator 186.4
Field Ratio 1
Phase 0
Spacing 78.4
Tower Orientation 240.4
Tower Reference Switch 0
Is the tower toploaded, sectionalized, or neither? Neither
Tower Parameters A
B
C
D

Directional Antenna : Tower - 3

Section Question Response
ASR Number Do you have an FCC Antenna Structure Registration (ASR) Number? Yes
ASR Number 1235891
Parameters Overall height above ground (including obstruction lighting) 89
Height of radiator above base insulator, or above base, if grounded 87.8
Electrical height of radiator 150.7
Field Ratio 1
Phase 70.7
Spacing 235.5
Tower Orientation 270.7
Tower Reference Switch 0
Is the tower toploaded, sectionalized, or neither? Neither
Tower Parameters A
B
C
D

Directional Antenna : Tower - 4

Section Question Response
ASR Number Do you have an FCC Antenna Structure Registration (ASR) Number? Yes
ASR Number 1235892
Parameters Overall height above ground (including obstruction lighting) 90.2
Height of radiator above base insulator, or above base, if grounded 88.9
Electrical height of radiator 152.6
Field Ratio 0.583
Phase 200.8
Spacing 218.3
Tower Orientation 310.1
Tower Reference Switch 0
Is the tower toploaded, sectionalized, or neither? Neither
Tower Parameters A
B
C
D

Directional Antenna Data - Nighttime

Section Question Response
Parameters Power 5.000
Latitude 41° 2` 48.8N
Longitude 112° 1` 39.8W
Theoretical RMS 738.57
Standard RMS 775.98
Specified Q
Augmentation Augmentation N
Augmentation RMS
Augmentation Table
Central Azimuth (degrees) Span (degrees) Radiation at Central Azimuth (mV/m)
Site Plat and Tower Sketch Attach an antenna site plat and a tower sketch. The antenna site plat should clearly show the following items: Boundary lines, roads, railroads, other obstructions, and the ground system or counterpoise. Number and dimensions of ground radials or height and dimensions of counterpoise. Spacing and orientation of each element in the array with respect to true north. A scale in meters. The tower sketch should include site elevation, radiator height above base insulator, tower height above ground level, overall tower height above ground without obstruction lighting, and overall height above ground with obstruction lighting.

Directional Antenna : Tower - 1

Section Question Response
ASR Number Do you have an FCC Antenna Structure Registration (ASR) Number? Yes
ASR Number 1235889
Parameters Overall height above ground (including obstruction lighting) 87.8
Height of radiator above base insulator, or above base, if grounded 86.5
Electrical height of radiator 148.5
Field Ratio 1
Phase 0
Spacing 0
Tower Orientation 0
Tower Reference Switch 0
Is the tower toploaded, sectionalized, or neither? Neither
Tower Parameters A
B
C
D

Directional Antenna : Tower - 2

Section Question Response
ASR Number Do you have an FCC Antenna Structure Registration (ASR) Number? Yes
ASR Number 1235890
Parameters Overall height above ground (including obstruction lighting) 109.7
Height of radiator above base insulator, or above base, if grounded 108.6
Electrical height of radiator 186.4
Field Ratio 0.912
Phase 96.2
Spacing 78.4
Tower Orientation 240.4
Tower Reference Switch 0
Is the tower toploaded, sectionalized, or neither? Neither
Tower Parameters A
B
C
D

Directional Antenna : Tower - 3

Section Question Response
ASR Number Do you have an FCC Antenna Structure Registration (ASR) Number? Yes
ASR Number 1235891
Parameters Overall height above ground (including obstruction lighting) 89
Height of radiator above base insulator, or above base, if grounded 87.8
Electrical height of radiator 150.7
Field Ratio 0.828
Phase 63.2
Spacing 235.5
Tower Orientation 270.7
Tower Reference Switch 0
Is the tower toploaded, sectionalized, or neither? Neither
Tower Parameters A
B
C
D

Directional Antenna : Tower - 4

Section Question Response
ASR Number Do you have an FCC Antenna Structure Registration (ASR) Number? Yes
ASR Number 1235892
Parameters Overall height above ground (including obstruction lighting) 90.2
Height of radiator above base insulator, or above base, if grounded 88.9
Electrical height of radiator 152.6
Field Ratio 0.54
Phase 32.3
Spacing 218.3
Tower Orientation 310.1
Tower Reference Switch 0
Is the tower toploaded, sectionalized, or neither? Neither
Tower Parameters A
B
C
D

Technical Certifications

Back to Top
Section Question Response
Environmental Effect By checking “Yes”, the applicant certifies that the facility will not have a significant environmental impact and complies with the maximum permissible electromagnetic exposure limits for controlled and uncontrolled environments (see 47 C.F.R. Section 1.1306). Unless the applicant can determine compliance through the use of the RF worksheets found on the FCC website (https://www.fcc.gov/sites/default/files/lms-radiofrequency-exposure-compliance-worksheets-radio-broadcast-stations.pdf), an Exhibit is required. Yes
Broadcast Facility Does the proposed facility comply with the applicable engineering standards and assignment requirements of 47 C.F.R. Sections 73.23, 73.24, 73.33, 73.37, 73.45, 73.150, 73.152, 73.160, 73.182, 73.186, 73.187, 73.189, and 73.1650?
Community of License Change - Section 307(b) Is the application being submitted to change the facility’s community of license? If ‘Yes’, an exhibit is required containing information demonstrating that the proposed community of license change constitutes a preferential arrangement of assignments under Section 307(b) of the Communications Act of 1934, as amended (47 U.S.C. Section 307(b))?

Certification

Back to Top
Section Question Response
General Certification Statements The Applicant waives any claim to the use of any particular frequency or of the electromagnetic spectrum as against the regulatory power of the United States because of the previous use of the same, whether by authorization or otherwise, and requests an Authorization in accordance with this application (See Section 304 of the Communications Act of 1934, as amended.).  
The Applicant certifies that neither the Applicant nor any other party to the application is subject to a denial of Federal benefits pursuant to §5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. § 862, because of a conviction for possession or distribution of a controlled substance. This certification does not apply to applications filed in services exempted under §1.2002(c) of the rules, 47 CFR . See §1.2002(b) of the rules, 47 CFR § 1.2002(b), for the definition of "party to the application" as used in this certification § 1.2002(c). The Applicant certifies that all statements made in this application and in the exhibits, attachments, or documents incorporated by reference are material, are part of this application, and are true, complete, correct, and made in good faith.  
Authorized Party to Sign

FAILURE TO SIGN THIS APPLICATION MAY RESULT IN DISMISSAL OF THE APPLICATION AND FORFEITURE OF ANY FEES PAID

Upon grant of this application, the Authorization Holder may be subject to certain construction or coverage requirements. Failure to meet the construction or coverage requirements will result in automatic cancellation of the Authorization. Consult appropriate FCC regulations to determine the construction or coverage requirements that apply to the type of Authorization requested in this application.

WILLFUL FALSE STATEMENTS MADE ON THIS FORM OR ANY ATTACHMENTS ARE PUNISHABLE BY FINE AND/OR IMPRISONMENT (U.S. Code, Title 18, §1001) AND/OR REVOCATION OF ANY STATION AUTHORIZATION (U.S. Code, Title 47, §312(a)(1)), AND/OR FORFEITURE (U.S. Code, Title 47, §503).

 
I declare, under penalty of perjury, that I am an authorized representative of the above-named applicant for the Authorization(s) specified above. JOHN C. WEBB


Attachments

Back to Top
File Name Uploaded By Attachment Type Description Upload Status
1219063_3540518.pdf Applicant All Purpose Distance to 25 mV/m. contour Done with Virus Scan and/or Conversion
1219063_3540519.pdf Applicant All Purpose Distance to 1000 mV/m. contour Done with Virus Scan and/or Conversion
1219063_3540523.pdf Applicant All Purpose Distance to 5 mV/m contour Done with Virus Scan and/or Conversion
1219063_3540524.pdf Applicant All Purpose Distance to 2 mV/m contour Done with Virus Scan and/or Conversion
1219063_3540525.pdf Applicant All Purpose Distance to 0.5 mV/m contour Done with Virus Scan and/or Conversion
1219063_3540526.pdf Applicant All Purpose Proposed 5.0, 2.0 and 0.5 mV/m contours Done with Virus Scan and/or Conversion
1219063_3540527.pdf Applicant All Purpose Proposed 25 and 1000 mV/m contours Done with Virus Scan and/or Conversion
1219063_3540531.pdf Applicant All Purpose Proposed antenna pattern plot Done with Virus Scan and/or Conversion
1219063_3540538.pdf Applicant All Purpose Proposed antenna pattern tabulation Done with Virus Scan and/or Conversion
1219063_3540545.pdf Applicant All Purpose Tabulation of stations studied Done with Virus Scan and/or Conversion
1219063_3540558.pdf Applicant All Purpose Interference study for proposed 25 kw operation Done with Virus Scan and/or Conversion
1219063_3540559.pdf Applicant All Purpose Interference study with expanded scale to demonstrate 5 mV/m contours Done with Virus Scan and/or Conversion
1219063_3540563.pdf Applicant All Purpose Distance tabulation to protected and interferring contours Done with Virus Scan and/or Conversion
1219063_596839.txt Applicant All Purpose PURPOSE OF THE APPLICATION Done with Virus Scan and/or Conversion
1219063_596840.txt Applicant All Purpose EXHIBIT 5 Done with Virus Scan and/or Conversion
1219063_596841.txt Applicant All Purpose EXHIBIT E-11 COMPLIANCE WITH REQUIRED FACILITIES Done with Virus Scan and/or Conversion
1219063_596842.txt Applicant All Purpose COVERAGE INFORMATION Done with Virus Scan and/or Conversion
1219063_596843.txt Applicant All Purpose INTERFERENCE STUDIES Done with Virus Scan and/or Conversion
1219063_596844.txt Applicant All Purpose GROUNDWAVE INTERFERENCE STUDY Done with Virus Scan and/or Conversion
1219063_596845.txt Applicant All Purpose EXHIBIT 18 Done with Virus Scan and/or Conversion
1219063_596846.txt Applicant All Purpose ENVIRONMENTAL CONSIDERATIONS Done with Virus Scan and/or Conversion
1219063_6087537.pdf Applicant All Purpose Proposed antenna pattern plot Done with Virus Scan and/or Conversion
1219063_6087538.pdf Applicant All Purpose Proposed antenna pattern tabulation Done with Virus Scan and/or Conversion
1219063_6087539.pdf Applicant All Purpose Distance to 25 mV/m. contour Done with Virus Scan and/or Conversion
1219063_6087540.pdf Applicant All Purpose Distance to 1000 mV/m. contour Done with Virus Scan and/or Conversion
1219063_6087541.pdf Applicant All Purpose Distance to 5 mV/m contour Done with Virus Scan and/or Conversion
1219063_6087542.pdf Applicant All Purpose Distance to 2 mV/m contour Done with Virus Scan and/or Conversion
1219063_6087543.pdf Applicant All Purpose Distance to 0.5 mV/m contour Done with Virus Scan and/or Conversion
1219063_6087544.pdf Applicant All Purpose Proposed 5.0, 2.0 and 0.5 mV/m contours Done with Virus Scan and/or Conversion
1219063_6087545.pdf Applicant All Purpose Proposed 25 and 1000 mV/m contours Done with Virus Scan and/or Conversion
1219063_6087546.pdf Applicant All Purpose Tabulation of stations studied Done with Virus Scan and/or Conversion
1219063_6087547.pdf Applicant All Purpose Interference study for proposed 25 kw operation Done with Virus Scan and/or Conversion
1219063_6087548.pdf Applicant All Purpose Interference study with expanded scale to demonstrate 5 mV/m contours Done with Virus Scan and/or Conversion