FIGURE 1 - COVERAGE MAP DEMONSTRATING THAT THE APPLICATION IS CONSIDERED A MINOR CHANGE PER SECTION 73.3572. RFR COMPLIANCE - THE PROPOSED FACILITIES WERE EVALUATED IN TERMS OF POTENTIAL RADIO FREQUENCY (RF) ENERGY EXPOSURE AT GROUND LEVEL TO WORKERS AND THE GENERAL PUBLIC. THE RADIATION CENTER FOR THE PROPOSED DTV ANTENNA IS LOCATED 10 METERS ABOVE GROUND LEVEL. THE MAXIMUM DTV ERP IS 15 KW (HORIZONTAL POLARIZATION). A GREATER THAN EXPECTED VERTICAL PLANE RELATIVE FIELD VALUE OF 0.13 (FOR ANGLES BELOW 60 DEGREES DOWNWARD) IS PRESUMED FOR THE ANTENNA'S DOWNWARD RADIATION (SEE FIGURE 2). THE CALCULATED POWER DENSITY AT A POINT 2 METERS ABOVE GROUND LEVEL IS 0.132 MW/CM2. THIS IS 32.8% OF THE FCC'S RECOMMENDED LIMIT OF 0.403 MW/CM2 FOR CHANNEL 36 FOR AN UNCONTROLLED ENVIRONMENT. THEREFORE, THE PROPOSAL WILL COMPLY WITH THE RF EMISSION RULES. ACCESS TO THE TRANSMITTING SITE WILL BE RESTRICTED AND APPROPRIATELY MARKED WITH RFR WARNING SIGNS. FURTHERMORE, A PROTOCOL WILL BE IN EFFECT WITH THE OTHER STATIONS IN THE EVENT THAT WORKERS OR OTHER AUTHORIZED PERSONNEL ENTER THE RESTRICTED AREA OR CLIMB THE TOWER TO ENSURE THAT APPROPRIATE MEASURES WILL BE TAKEN TO ASSURE WORKER SAFETY WITH RESPECT TO RADIO FREQUENCY RADIATION EXPOSURE. SUCH MEASURES INCLUDE REDUCING THE AVERAGE EXPOSURE BY SPREADING OUT THE WORK OVER A LONGER PERIOD OF TIME, WEARING ACCEPTED RFR PROTECTIVE CLOTHING AND/OR RFR EXPOSURE. FURTHERMORE, IT IS NOTED THAT THIS TECHNICAL EXHIBIT ONLY ADDRESSES THE POTENTIAL FOR RADIO FREQUENCY ELECTROMAGNETIC FIELD EXPOSURE. THE PROPOSAL IS LOCATED OUTSIDE OF THE MEXICAN AND CANADIAN COORDINATION ZONES. THE PROPOSED OPERATION WILL PROVIDE THE NECESSARY PROTECTION TO RADIO ASTRONOMY INSTALLATIONS AND FCC MONITORING STATIONS.