AN ENGINEERING ANALYSIS WAS PERFORMED TO DETERMINE WHETHER THE FACILITIES PROPOSED HEREIN COMPLY WITH THE MAXIMUM PERMISSIBLE EXPOSURE STANDARDS OUTLINED IN 47CFR1.1310 AS REGARDS HUMAN EXPOSURE TO RADIOFREQUENCY ELECTROMAGNETIC FIELDS AND WHETHER ENVIRONMENTAL PROCESSING WOULD BE REQUIRED. THE APPLICANT PROPOSES TO OPERATE AT 0.25 KILOWATTS, VERTICALLY POLARIZED, USING A SCALA FMV ANTENNA MOUNTED ON A MAST 3 METERS ABOVE THE ROOF OF A SCHOOLHOUSE. THIS ANTENNA CONSISTS OF A SINGLE RADIATING ELEMENT. THE FLOOR OF THE HIGHEST OCCUPIED STORY OF THE BUILDING IS 10 METERS BELOW THE RADIATION CENTER OF THE ANTENNA. THE ATTIC SPACE IMMEDIATELY BELOW THE ANTENNA IS ACCESSIBLE ONLY BY PORTABLE LADDER. THE COMMISSION'S FMMODEL COMPUTER SOFTWARE WAS USED TO CALCULATE THE RADIOFREQUENCY ELECTROMAGNETIC POWER DENSITY IN A PLANE 2 METERS ABOVE THE FLOOR OF THE HIGHEST OCCUPIED STORY OF THE BUILDING AS A FUNCTION OF THE DISTANCE FROM THE ANTENNA SUPPORT STRUCTURE. A COPY OF THE GRAPHICAL OUTPUT OF THIS PROGRAM IS ATTACHED. ELEVATION PATTERN DATA WAS TAKEN FROM THE MANUFACTURER'S PUBLISHED SPECIFICATIONS AND ENTERED INTO THE FMMODEL ANTENNA DATABASE. THE HIGHEST POWER DENSITY OCCURS AT A POINT 12.5 METERS FROM THE BASE OF THE SUPPORT MAST AND IS EQUAL TO 13.7 UW/CM^2. THIS REPRESENTS 6.85% OF THE GENERAL PUBLIC/UNCONTROLLED MPE STANDARD. APPROPRIATE SIGNS WILL BE INSTALLED ON THE ACCESS HATCH TO THE ATTIC SPACE WARNING WORKERS AND OTHERS THAT THE MAXIMUM PERMISSIBLE EXPOSURE STANDARD MAY BE EXCEEDED AT LOCATIONS IN THE ATTIC. THE APPLICANT BELIEVES THAT THE FACILITIES PROPOSED HEREIN CONFORM TO THE MPE STANDARDS OUTLINED IN 47CFR1.1310 AND THAT ENVIRONMENTAL PROCESSING IS NOT WARRANTED.