THE PROPOSED FACILITIES WERE EVALUATED IN TERMS OF POTENTIAL RADIO FREQUENCY (RF) ENERGY EXPOSURE AT GROUND LEVEL TO WORKERS AND THE GENERAL PUBLIC. THE RADIATION CENTER FOR THE PROPOSED DTV ANTENNA IS LOCATED 43 METERS ABOVE GROUND LEVEL. THE MAXIMUM DTV ERP IS 10 KW (HORIZONTAL POLARIZATION). A CONSERVATIVE VERTICAL PLANE RELATIVE FIELD VALUE OF 0.25 (FOR ANGLES BELOW 60 DEGREES DOWNWARD) IS PRESUMED FOR THE ANTENNA'S DOWNWARD RADIATION. THE CALCULATED POWER DENSITY AT A POINT 2 METERS ABOVE GROUND LEVEL IS 0.0046 MW/CM2. THIS IS 2.3% OF THE FCC'S RECOMMENDED LIMIT OF 0.2 MW/CM2 FOR CHANNEL 8 FOR AN UNCONTROLLED ENVIRONMENT. THEREFORE, BASED ON THE RESPONSIBILITY THRESHOLD OF 5%, THE PROPOSAL WILL COMPLY WITH THE RF EMISSION RULES. ACCESS TO THE TRANSMITTING SITE WILL BE RESTRICTED AND APPROPRIATELY MARKED WITH RFR WARNING SIGNS. FURTHERMORE, AS THIS IS A MULTI-USER SITE, A PROTOCOL WILL BE IN EFFECT WITH THE OTHER STATIONS IN THE EVENT THAT WORKERS OR OTHER AUTHORIZED PERSONNEL ENTER THE RESTRICTED AREA OR CLIMB THE TOWER TO ENSURE THAT APPROPRIATE MEASURES WILL BE TAKEN TO ASSURE WORKER SAFETY WITH RESPECT TO RADIO FREQUENCY RADIATION EXPOSURE. SUCH MEASURES INCLUDE REDUCING THE AVERAGE EXPOSURE BY SPREADING OUT THE WORK OVER A LONGER PERIOD OF TIME, WEARING ACCEPTED RFR PROTECTIVE CLOTHING AND/OR RFR EXPOSURE MONITORS OR SCHEDULING WORK WHEN THE STATIONS ARE AT REDUCED POWER OR SHUT DOWN. THE PROPOSED OPERATION APPEARS TO BE OTHERWISE CATEGORICALLY EXCLUDED FROM ENVIRONMENTAL PROCESSING. FINALLY, IT IS NOTED THAT THIS STATEMENT ONLY ADDRESSES THE POTENTIAL FOR RADIOFREQUENCY ELECTROMAGNETIC FIELD EXPOSURE. ALL OTHER ASPECTS OF THE ENVIRONMENTAL PROCESSING ANALYSIS WILL BE OR ALREADY HAVE BEEN PROVIDED TO THE FCC BY THE TOWER OWNER.