RF RADIATION FROM THE PROPOSED FACILITY HAS BEEN REVIEWED IN ACCORDANCE WITH THE RADIO FREQUENCY PROTECTION GUIDES ADOPTED BY THE COMMISSION IN OET BULLETIN NO. 65, EDITION 97-01. RF RADIATION FROM THE PROPOSED FACILITY WILL NOT HAVE A SIGNIFICANT ENVIRONMENTAL IMPACT. UTILIZING THE EQUATION 10 OF OET BULLETIN 65, THE WORST CASE POWER DENSITY AT GROUND LEVEL HAS BEEN CALCULATED TO BE 0.8898 UW/CM SQUARED OR 0.4449% OF THE ALLOWABLE FCC STANDARD OF 200 UW/CM SQUARED FOR FM STATIONS IN AN UNCONTROLLED ENVIRONMENT. ADDITIONALLY, SINCE THE PROPOSED ERP IS LESS THAN 100 WATTS, THE PROPOSED FACILITY IS BELIEVED TO BE CATEGORICALLY EXCLUDED FROM ENVIRONMENTAL PROCESSING