THE PROPOSED ANTENNA SYSTEM CONSISTS OF A PSI MODEL LP8OI 8 SLOT, HORIZONTALLY POLARIZED, ANTENNA, WITH A RADIATION CENTER 35 METERS ABOVE GROUND. FORMULA 10 OF OET BULLETIN NO. 65, EDITION 97-01, PAGE 22, HAS BEEN USED TO CALCULATE POWER DENSITY. A VALUE F OF 0.3 HAS BEEN USED TO CALCULATE THE POWER DENSITY 2 METERS ABOVE GROUND. THE MAXIMUM POWER DENSITY IS 41.4 UW/CM SQUARED FOR AN ERP OF 15000 WATTS. THIS VALUE IS 12.2 % OF THE ALLOWABLE 339.3 UW/CM SQUARED POWER DENSITY FOR UNCONTROLLED ENVIRONMENTS FOR TV CHANNEL 20 AND, THUS, IS BELIEVED TO COMPLY WITH OET-65 GUIDELINES FOR PUBLIC EXPSOURE. THE TOWER BASE WILL BE FENCED TO PREVENT UNAUTHORIZED ACCESS. THE APPLICANT WILL REDUCE, OR CEASE, TRANSMISSION AS REQUIRED TO MEET FCC OET-65 GUIDELINES FOR WORKER EXPOSURE.