THE AS BUILT ANTENNA CENTER OF RADIATION IS 2 METERS BELOW THE VALUE LISTED IN THE CONSTRUCTION PERMIT (CP, BMPH-20151005AAF). SPECIFICALLY, THE AS-BUILT VALUE IS 56 METERS ABOVE GROUND LEVEL (AGL) WHEREAS THE VALUE LISTED IN THE CP IS 58 METERS AGL. THIS 2 METER HEIGHT DISCREPANCY IS PERMITTED BY SECTION 73.1690(C)(1) AS WKLA-FM IS A NONDIRECTIONAL SECTION 73.215 STATION, THERE ARE NO SPECIAL OPERATING CONDITIONS AND THE AS-BUILT OPERATION COMPLIES WITH THE FCCS RFR GUIDELINES (SEE BELOW). RFR COMPLIANCE: THE WKLA-FM FACILITIES WERE EVALUATED IN TERMS OF POTENTIAL RADIO FREQUENCY (RF) ENERGY EXPOSURE TO WORKERS AND THE GENERAL PUBLIC. THE TRANSMITTING ANTENNA IS SIDE-MOUNTED AT THE 56 METER LEVEL ON THE EXISTING TOWER (ASRN 1261248). USING A GREATER THAN EXPECTED VERTICAL PLANE RELATIVE FIELD VALUE OF 0.45 (FOR ANGLES BELOW 60 DEGREES DOWNWARD), A TOTAL ERP OF 6.8 KW (HORIZONTAL AND VERTICAL POLARIZATION), THE CALCULATED POWER DENSITY AT 2 METERS ABOVE GROUND LEVEL AT THE BASE OF THE TOWER IS 0.0158 MILLIWATT PER SQUARE CENTIMETER (MW/CM2), OR 7.9 PERCENT OF THE COMMISSION'S RECOMMENDED LIMIT FOR AN UNCONTROLLED ENVIRONMENT (0.2 MW/CM2 FOR FM FREQUENCIES). HOWEVER, AS THIS IS A MULTIPLE-USER SITE ALL EXISTING AND AUTHORIZED BROADCAST FACILITIES IN THE VICINITY MUST BE CONSIDERED IN THE RFR EVALUATION. THE CALCULATIONS ARE SUMMARIZED BELOW: WKLA-FM, CH 242A, TOTAL ERP 6.8 KW, VPRF 0.45, DIST. 54 M, PD 0.0158 UW/CM2, 7.9% OF LIMIT WLDN(FM), CH 254A, TOTAL ERP 11 KW, VPRF 0.45, DIST. 54 M, PD 0.0255 UW/CM2, 12.8% OF LIMIT W224CA, CH 224D, TOTAL ERP 0.32 KW, VPRF 1, DIST. 53 M, PD 0.0038 UW/CM2, 1.9% OF LIMIT [NOTE: W285DY OPERATION NOT CONSIDERED AS TOTAL ERP IS LESS THAN 100 W] THE SUMMATION OF THE ABOVE FRACTIONS OF THE ANSI LIMIT FOR EACH OF THE ABOVE STATIONS IS 0.226. SINCE THIS IS LESS THAN UNITY, THE COMBINED POWER DENSITY AT 2 METERS ABOVE GROUND LEVEL WILL BE LESS THAN THE ANSI RECOMMENDED LIMIT APPLICABLE TO GENERAL POPULATION/UNCONTROLLED EXPOSURE AREAS. THUS, IT IS BELIEVED THAT THE WKLA-FM FACILITY IS IN FULL COMPLIANCE WITH THE FCCS REQUIREMENTS WITH REGARD TO RADIO FREQUENCY RADIATION EXPOSURE. ACCESS TO THE TRANSMITTING SITE IS RESTRICTED AND APPROPRIATELY MARKED WITH RFR WARNING SIGNS. FURTHERMORE, A PROTOCOL SHALL BE IN EFFECT IN THE EVENT THAT WORKERS OR OTHER AUTHORIZED PERSONNEL ENTER THE RESTRICTED AREA OR CLIMB THE TOWER TO ENSURE THAT APPROPRIATE MEASURES WILL BE TAKEN TO ASSURE WORKER SAFETY WITH RESPECT TO RF ENERGY EXPOSURE.