THE PROPOSED ANTENNA SYSTEM CONSISTS OF A DIELECTRIC, CIRCULARLY POLARIZED, THREE BAY, 1.0 WAVE SPACED ANTENNA, WITH A RADIATION CENTER 95.8 METERS ABOVE GROUND. UTILIZING FORMULA 10 OF OET BULLETIN NO. 65, EDITION 97-01, A VALUE F OF 0.38 HAS BEEN USED TO CALCULATE THE POWER DENSITY 2 METERS ABOVE GROUND. THE MAXIMUM POWER DENSITY IS 6.3 UW/CM SQUARED FOR AN ERP OF 6,000 WATTS V. AND 6,000 WATTS H. POLARIZATION. THIS VALUE IS 3.15 % OF THE ALLOWABLE 200 UW/CM SQUARED POWER DENSITY FOR UNCONTROLLED ENVIRONMENTS AND, THUS, IS BELIEVED TO BE CATEGORICALLY EXCLUDED FROM ENVIRONMENTAL PROCESSING. THE TOWER BASE WILL BE FENCED TO PREVENT UNAUTHORIZED ACCESS. THE APPLICANT WILL REDUCE, OR CEASE, TRANSMISSION AS REQUIRED TO MEET FCC OET-65 GUIDELINES FOR WORKER EXPOSURE.