THE FACILITY PROPOSED IN THE INSTANT APPLICATION IS COMPLIANT WITH 47 CFR SECTION 74.1204 WITH RESPECT TO CO-CHANNEL, FIRST-ADJACENT, SECOND-ADJACENT AND THIRD-ADJACENT PROTECTIONS AND I.F. CHANNEL PROTECTIONS OF ALL CURRENT APPLICATIONS AND AUTHORIZATIONS. THE APPLICANT ACKNOWLEDGES SECOND OR THIRD ADJACENT CHANNEL OVERLAP WITH FACILITY ID 52394, WCNR, CHANNEL 291A, KESWICK, VA. THE AMOUNT OF SIGNAL FROM WCNR ARRIVING AT THE APPLICANT'S PROPOSED TRANSMITTER SITE IS 118 DBU. USING THE 40 DB UNDESIRED-TO-DESIRED RATIO METHOD FOR DETERMINING SECOND OR THIRD ADJACENT CHANNEL INTERFERENCE, THE PERTINENT INTERFERING CONTOUR IS 158 DBU. ACCORDING TO THE FCC ONLINE COMPUTER PROGRAM 'FM AND TV PROPAGATION CURVES CALCULATIONS', THE INTERFERING CONTOUR EXTENDS LESS THAN 1 METER FROM THE ANTENNA LOCATION PROPOSED IN THE INSTANT APPLICATION. SINCE THE APPLICANT HAS PROPOSED A HEIGHT ABOVE GROUND LEVEL OF 41 METERS, AND THE DISTANCE TO THE INTERFERING CONTOUR IS LESS THAN 1 METER, IT IS IMPOSSIBLE FOR THE INTERFERING CONTOUR TO REACH THE GROUND OR ANY POPULATION. THUS THIS APPLICATION IS COMPLIANT WITH 47 CFR SECTION 74.1204 WITH RESPECT TO SECOND OR THIRD ADJACENT CHANNEL INTERFERENCE. THE APPLICANT ACKNOWLEDGES SECOND OR THIRD ADJACENT CHANNEL OVERLAP WITH LICENSED FM TRANSLATOR FACILITY ID 18866, CHANNEL 295D, W295BR, CHARLOTTESVILLE, VA. THE FACILITY PROPOSED IN THE INSTANT APPLICATION AND THE LICENSED FACILITY W295BR ARE SEPARATED BY 130 METERS. THE AMOUNT OF SIGNAL FROM LICENSED FACILITY W295BR ARRIVING AT THE APPLICANT'S PROPOSED TRANSMITTER SITE IS 105 DBU. USING THE 40 DB UNDESIRED-TO-DESIRED RATIO METHOD FOR DETERMINING SECOND OR THIRD ADJACENT CHANNEL INTERFERENCE, THE PERTINENT INTERFERING CONTOUR IS 145 DBU. ACCORDING TO THE FCC ONLINE COMPUTER PROGRAM 'FM AND TV PROPAGATION CURVES CALCULATIONS', THE INTERFERING CONTOUR EXTENDS 1 METER FROM THE ANTENNA LOCATION PROPOSED IN THE INSTANT APPLICATION. SINCE THE APPLICANT HAS PROPOSED A HEIGHT ABOVE GROUND LEVEL OF 41 METERS, AND THE DISTANCE TO THE INTERFERING CONTOUR IS 1 METER, IT IS IMPOSSIBLE FOR THE INTERFERING CONTOUR TO REACH THE GROUND OR ANY POPULATION. THUS THIS APPLICATION IS COMPLIANT WITH 47 CFR SECTION 74.1204 WITH RESPECT TO SECOND OR THIRD ADJACENT CHANNEL INTERFERENCE. THE APPLICANT ACKNOWLEDGES SECOND OR THIRD ADJACENT CHANNEL OVERLAP WITH THE PENDING APPLICATION BPFT-20150527AAD FOR FM TRANSLATOR FACILITY ID 18866, CHANNEL 295D, W295BR, CHARLOTTESVILLE, VA. THE FACILITY PROPOSED IN THE INSTANT APPLICATION AND THE PROPOSED BPFT-20150527AAD FACILITY FOR W295BR ARE SEPARATED BY 18 METERS. THE AMOUNT OF SIGNAL FROM THE BPFT-20150527AAD PROPOSED FACILITY FOR W295BR ARRIVING AT THE APPLICANT'S PROPOSED TRANSMITTER SITE IS 122 DBU. USING THE 40 DB UNDESIRED-TO-DESIRED RATIO METHOD FOR DETERMINING SECOND OR THIRD ADJACENT CHANNEL INTERFERENCE, THE PERTINENT INTERFERING CONTOUR IS 162 DBU. ACCORDING TO THE FCC ONLINE COMPUTER PROGRAM 'FM AND TV PROPAGATION CURVES CALCULATIONS', THE INTERFERING CONTOUR EXTENDS LESS THAN 1 METER FROM THE ANTENNA LOCATION PROPOSED IN THE INSTANT APPLICATION. SINCE THE APPLICANT HAS PROPOSED A HEIGHT ABOVE GROUND LEVEL OF 41 METERS, AND THE DISTANCE TO THE INTERFERING CONTOUR IS LESS THAN 1 METER, IT IS IMPOSSIBLE FOR THE INTERFERING CONTOUR TO REACH THE GROUND OR ANY POPULATION. THUS THIS APPLICATION IS COMPLIANT WITH 47 CFR SECTION 74.1204 WITH RESPECT TO SECOND OR THIRD ADJACENT CHANNEL INTERFERENCE. THE APPLICANT ACKNOWLEDGES SECOND OR THIRD ADJACENT CHANNEL OVERLAP WITH THE PENDING APPLICATION BPFT-20150527AAD FOR FM TRANSLATOR FACILITY ID 18866, CHANNEL 295D, W295BR, CHARLOTTESVILLE, VA. THE FACILITY PROPOSED IN THE INSTANT APPLICATION AND THE PROPOSED BPFT-20150527AAD FACILITY FOR W295BR ARE SEPARATED BY 18 METERS. THE AMOUNT OF SIGNAL FROM THE APPLICANT'S PROPOSED TRANSMITTER SITE ARRIVING AT THE BPFT-20150527AAD PROPOSED FACILITY FOR W295BR IS 122 DBU. USING THE 40 DB UNDESIRED-TO-DESIRED RATIO METHOD FOR DETERMINING SECOND OR THIRD ADJACENT CHANNEL INTERFERENCE, THE PERTINENT INTERFERING CONTOUR IS 162 DBU. ACCORDING TO THE FCC ONLINE COMPUTER PROGRAM 'FM AND TV PROPAGATION CURVES CALCULATIONS', THE INTERFERING CONTOUR EXTENDS LESS THAN 1 METER FROM THE BPFT-20150527AAD PROPOSED FACILITY FOR W295BR. SINCE THE BPFT-20150527AAD PROPOSED FACILITY FOR W295BR HAS PROPOSED A HEIGHT ABOVE GROUND LEVEL OF 23 METERS, AND THE DISTANCE TO THE INTERFERING CONTOUR IS LESS THAN 1 METER, IT IS IMPOSSIBLE FOR THE INTERFERING CONTOUR TO REACH THE GROUND OR ANY POPULATION. THUS THIS APPLICATION IS COMPLIANT WITH 47 CFR SECTION 74.1204 WITH RESPECT TO SECOND OR THIRD ADJACENT CHANNEL INTERFERENCE.